Product manual
Table Of Contents
- Table of Contents
- List of Figures
- List of Tables
- Chapter 1 ABOUT THIS MANUAL
- 1.1 AUDIENCE
- 1.2 MANUAL ORGANIZATION
- 1.3 TERMINOLOGY AND CONVENTIONS
- 1.4 REFERENCES
- Chapter 2 GENERAL DESCRIPTION
- 2.1 PRODUCT OVERVIEW
- 2.2 KEY FEATURES
- 2.3 REGULATORY COMPLIANCE STANDARDS
- 2.4 HARDWARE REQUIREMENTS
- Chapter 3 INSTALLATION
- 3.1 SAFETY, HANDLING, & ELECTROSTATIC DISCHARGE PROTECTION
- 3.1.1 Safety Precautions
- 3.1.2 Handling
- 3.1.3 Electrostatic Discharge (ESD) Protection
- 3.2 SPACE REQUIREMENTS
- Figure 3-1 Dimensions for the Maxtor Atlas 10K V Hard Disk Drives
- 3.2.1 Shock Feet
- 3.3 UNPACKING INSTRUCTIONS
- Figure 3-2 Drive Packing Assembly
- 3.4 HARDWARE OPTIONS
- 3.4.1 Configuration Jumpers and Connections
- 3.4.2 Jumper Options on the 68-Pin Wide PCB
- Figure 3-3 Jumper Locations on the 68-Pin Wide SCSI Drive PCB
- Table 3-1 SCSI ID Selection on Option Connector (68-Pin SCSI Connector Drives)
- 3.4.2.1 Write Protection
- 3.4.2.2 Delay Spin (DS), Stagger Spin (SS)
- Option 1 (No jumpers installed):
- Option 2 (Delay Spin jumper installed):
- 3.4.2.3 Single-Ended Operation - Force SE (Disable LVD)
- 3.4.2.4 Remote Busy and Fault Displays
- Remote Fault LED
- 3.4.3 SCA-2 80-Pin Connector Versions
- 3.4.3.1 Termination for the 80-Pin SCA-2 Connector Versions
- 3.4.3.2 SCSI ID for SCA-2 Versions
- Figure 3-4 Pin Locations on SCA-2 Connector
- Table 3-2 SCSI ID Pin Assignments (SCA-2 Connector Versions of the Disk Drive)
- 3.4.3.3 Spin Up for the 80-Pin SCA-2 Connector Versions
- Table 3-3 Spin Up on Power On Options
- 3.4.3.4 Activity LED for SCA-2 Connector Versions
- 3.5 INTERFACE CONNECTOR (J1)
- Figure 3-5 J1 Interface Connector Configurations
- 3.5.1 68-Pin Wide SCSI Connector - LVD
- Table 3-4 68-Pin Wide LVD Pin Assignments
- 3.5.1.1 68-Pin Wide Mating Connector
- 3.5.2 80-Pin SCA-2 SCSI Connector - LVD
- Table 3-5 80-Pin SCA-2 LVD Pin Assignments
- 3.5.2.1 80-Pin SCA-2 Mating Connectors
- 3.5.3 68-Pin Wide Single-Ended SCSI Connector
- Table 3-6 68-Pin Wide Single-Ended Pin Assignments
- 3.5.4 80-Pin SCA-2 Single-Ended SCSI Connector
- Table 3-7 80-Pin SCA-2 Single-Ended Pin Assignments
- 3.6 DRIVE MOUNTING and installation
- 3.6.1 Orientation
- Figure 3-6 Mounting Dimensions Maxtor Atlas 10K V Drives
- 3.6.2 Mounting Screw Clearance
- Figure 3-7 Mounting Screw Clearance for Maxtor Atlas 10K V Drive
- 3.6.3 Mounting
- 3.6.4 Ventilation
- Figure 3-8 Lengthwise Airflow Cooling
- Figure 3-9 Crosswise Airflow Cooling
- Chapter 4 SPECIFICATIONS
- 4.1 SPECIFICATION SUMMARY
- Table 4-1 Specifications
- 4.2 FORMATTED CAPACITY
- Table 4-2 Formatted Capacity
- 4.3 DATA TRANSFER RATES
- 4.4 TIMING SPECIFICATIONS
- Table 4-3 Timing Specifications for Maxtor Atlas 10K V
- 4.5 POWER
- 4.5.1 Power Sequencing
- 4.5.2 Power Reset Limits
- Table 4-4 Power Reset Limits1
- 4.5.3 Drive Power Dissipation
- Table 4-5 Power Dissipation in Various Modes (Low-Profile Drives)
- 4.6 ACOUSTICS
- Table 4-6 Acoustical Characteristics-Sound Power per ISO 7779
- 4.6.1 Acoustic Toned Quality
- 4.7 MECHANICAL
- 4.8 ENVIRONMENTAL CONDITIONS
- Table 4-7 Environmental Specifications
- 4.9 ELECTROMAGNETIC CONDITIONS
- 4.9.1 EMI/RFI Susceptibility
- 4.9.2 ESD
- 4.9.3 Sensitivity to Magnetic Fields
- 4.10 SHOCK AND VIBRATION
- Table 4-8 Shock and Vibration Specifications
- 4.11 RELIABILITY
- 4.12 DISK ERRORS
- Table 4-9 Error Rates
- Chapter 5 SCSI Description
- 5.1 Overview of the SCSI Command Descriptions
- Table 5-1 Supported SCSI Commands
- 5.2 Command Descriptor Block
- Table 5-2 Typical (6-Byte) Command Descriptor Block-Data Format
- Table 5-3 Command Descriptor Block-Field Descriptions
- Table 5-4 Typical (6-Byte) Command Descriptor Block - Data Format
- Table 5-5 Command Descriptor Block Control Field-Field Descriptions
- 5.3 Status/Error Reporting
- Table 5-6 Status Codes
- 5.4 Linked Commands
- 5.5 DATA Transfer Command Components
- Table 5-7 Length Fields
- Table 5-8 DATA-Phase Command Contents
- 5.6 SCSI COMMAND DESCRIPTIONS
- 5.7 CHANGE OPERATING DEFINITION (40h)
- Table 5-9 CHANGE DEFINITION Command Descriptor Block-Data Format
- Table 5-10 CHANGE DEFINITION-Field Descriptions
- 5.8 FORMAT UNIT Command (04h)
- Table 5-11 FORMAT UNIT Command Descriptor Block-Data Format
- Table 5-12 FORMAT UNIT Command-Field Descriptions
- 5.8.1 Five Forms of FORMAT UNIT Command s
- Table 5-13 FORMAT UNIT Command Supported Options
- 5.8.2 FORMAT UNIT Parameter List
- Table 5-14 FORMAT UNIT Parameter List-Data Format
- 5.8.2.1 FORMAT UNIT Defect List Header
- Table 5-15 .FORMAT UNIT Defect List Header-Data Format
- Table 5-16 FORMAT UNIT Defect List Header-Field Descriptions
- 5.8.2.2 FORMAT UNIT Defect Descriptor-Block Format
- Table 5-17 FORMAT UNIT Defect Descriptor-Block Format
- 5.8.2.3 FORMAT UNIT Defect Descriptor - Physical Sector and Bytes From Index Format
- Table 5-18 FORMAT UNIT Defect Descriptor- Physical Sector and Bytes From Index Format
- 5.8.2.4 FORMAT UNIT Initialization Pattern Descriptor
- Table 5-19 FORMAT UNIT Initialization Pattern Descriptor-Data Format
- Table 5-20 FORMAT UNIT Initialization Pattern Descriptor-Field Descriptions
- Table 5-21 FORMAT UNIT Initialization Pattern Type
- 5.9 INQUIRY Command (12h)
- Table 5-22 INQUIRY Command Descriptor Block-Data Format
- Table 5-23 INQUIRY Command Descriptor Block-Field Descriptions
- 5.9.1 Standard Inquiry Data Page
- Table 5-24 Standard Inquiry Data Page-Data Format
- Table 5-25 Standard Inquiry Data Page-Field Descriptions
- 5.9.2 Vital Product Data Pages
- 5.9.2.1 Supported Vital Product Data Pages Page (00h)
- Table 5-26 Supported Vital Product Data Pages -Data Format
- Table 5-27 Vital Product Data-Page Codes
- 5.9.2.2 Unit Serial Number Page (80h)
- Table 5-28 Unit Serial Number Page-Data Format
- Table 5-29 Unit Serial Number Page-Field Descriptions
- 5.9.2.3 Implemented Operating Definition Page (81h)
- Table 5-30 Implemented Operating Definition Page-Data Format
- Table 5-31 Implemented Operating Definition Page-Field Descriptions
- 5.9.2.4 ASCII Implemented Operating Definition Page (82h)
- Table 5-32 ASCII Implemented Operating Definition Page - Data Format
- 5.9.2.5 Device Identification Page (83h) (SCSI-3 ONLY)
- Table 5-33 Device Identification Page - Data Format
- Table 5-34 Device Identification Page - Field Description
- 5.9.2.6 Command Support Data Pages
- Table 5-35 Command Support Data Page-Data Format
- Table 5-36 Command Support Data Page-Field Descriptions
- Table 5-37 Command Support Data Page Command or Operation Codes
- 5.10 LOG SELECT Command (4Ch)
- Table 5-38 LOG SELECT Command Descriptor Block-Data Format
- Table 5-39 LOG SELECT Command Descriptor Block-Field Descriptions
- 5.11 LOG SENSE Command (4Dh)
- Table 5-40 Disk Drive Log Pages
- 5.11.1 LOG SENSE Command Descriptor Block
- Table 5-41 LOG SENSE Command Descriptor Block-Data Format
- Table 5-42 LOG SENSE Command Descriptor Block-Field Descriptions
- 5.11.2 LOG SENSE Log Pages
- Table 5-43 LOG SENSE Log Page Format-Data Format
- Table 5-44 LOG SENSE Log Page Format-Field Descriptions
- Table 5-45 Generic Log Parameter-Data Format
- Table 5-46 Generic Log Parameter-Field Descriptions
- 5.12 MODE SELECT (6) Command (15h)
- Table 5-47 MODE SELECT (6) Command Descriptor Block-Data Format
- Table 5-48 MODE SELECT (6) Command Field Descriptions
- 5.12.1 Initiator-Changeable Mode Pages
- Table 5-49 Initiator-Changeable Mode Pages
- 5.12.2 Mode Page Types
- Table 5-50 Mode Page Types
- 5.12.3 Mode Parameter List
- Table 5-51 Mode Parameter List-Data Format
- Table 5-52 Mode Parameter List-Field Descriptions
- Table 5-53 Mode Parameter Header (6-Byte)-Data Format
- Table 5-54 Mode Parameter Header- Field Descriptions
- Table 5-55 Mode Parameter Block Descriptor-Data Format
- Table 5-56 Mode Parameter Block Descriptor-Field Descriptions
- 5.12.4 Categories of Changeable Pages
- Table 5-57 Categories of Changeable Pages
- 5.12.5 Unit Attention Condition Page (00h)
- Table 5-58 Unit Attention Condition Page (Page 0)
- Table 5-59 Unit Attention Condition Page (Page 0)
- 5.12.6 Read-Write Error Recovery Page (01h)
- Table 5-60 Read-Write Error Recovery Page-(Page 1)
- Table 5-61 Read-Write Error Recovery Page - Field Descriptions
- 5.12.7 Disconnect-Reconnect Page (02h)
- Table 5-62 Disconnect-Reconnect Page (Page 2)
- Table 5-63 Disconnect-Reconnect-Field Descriptions (Page 2)
- 5.12.8 Verify Error Recovery Page (07h)
- Table 5-64 Verify Error Recovery Page-(Page 7)
- Table 5-65 Verify Error Recovery Page-Field Descriptions (Page 7)
- 5.12.9 Caching Page (08h)
- Table 5-66 Caching Page-(Page 8)
- Table 5-67 Caching Page - Field Descriptions
- 5.12.10 Control Mode Page (0Ah)
- Table 5-68 Control Mode Page - Data Format (Page 0Ah)
- Table 5-69 Control Mode Page-Field Descriptions
- 5.12.11 Notch and Partition Page (0Ch)
- Table 5-70 Notch and Partition Page-(Page 0Ch)
- Table 5-71 Notch and Partition Page-Field Descriptions
- 5.12.12 Port Control Mode Page (19h)
- Table 5-72 Port Control Page Short Format
- Table 5-73 Port Control Page Long Format
- 5.12.12.1 Margin Control Subpage (Sub Page 1 of Mode Page 19)
- Table 5-74 Margin Control Subpage (01h)
- Table 5-75 Field Descriptions
- 5.12.12.2 Saved Training Configuration Values Subpage (Sub Page 2 of Mode Page 19)
- Table 5-76 Saved Training Configuration Subpage (02h)
- 5.12.12.3 Negotiated Settings Subpage (Sub Page 3 of Mode Page 19)
- Table 5-77 Negotiated Settings Subpage (03h)
- Table 5-78 Transceiver Period Factor
- Table 5-79 Transceiver Mode
- 5.12.12.4 Report Transfer Capabilities Subpage - (Sub Page 4 of Mode Page 19)
- Table 5-80 Report Transfer Capabilities Subpage (4)
- Table 5-81 Field Descriptions
- 5.12.13 Information Exceptions Control Page (1Ch)
- Table 5-82 Information Exceptions Control Page-(Page 1Ch)
- Table 5-83 Information Exceptions Control Page-Field Descriptions (Page 1Ch)
- Table 5-84 Codes Used by the MRIE Field
- 5.13 MODE SELECT (10) Command (55h)
- Table 5-85 MODE SELECT (10) Command Descriptor Block-Data Format
- Table 5-86 Mode Parameter Header (10-Byte)-Data Format
- Table 5-87 Mode Parameter Block Descriptor-Data Format
- Table 5-88 Mode Parameter Block Descriptor-Field Descriptions
- 5.14 MODE SENSE (6) Command (1Ah)
- Table 5-89 MODE SENSE (6) Command Descriptor Block-Data Format
- Table 5-90 MODE SENSE Command-Field Descriptions
- Table 5-91 Mode Parameter Header (6 Byte)-Data Format
- Table 5-92 Mode Parameter Header and Block Descriptor-Field Descriptions
- 5.14.1 Read-Only Mode Pages
- Table 5-93 Read-Only Mode Pages
- 5.14.2 Format Device Page (03h)
- Table 5-94 Format Device Page-(Page 3)
- Table 5-95 Format Device Page-Field Descriptions (Page 3)
- 5.14.3 Rigid Disk Geometry Page (04h)
- Table 5-96 Rigid Disk Geometry Page-(Page 4)
- Table 5-97 Rigid Disk Geometry Page-Field Descriptions (Page 4)
- 5.15 MODE SENSE (10) Command (5Ah)
- Table 5-98 MODE SENSE (10) Command Descriptor Block-Data Format
- Table 5-99 Mode Parameter Header (10 Byte)-Data Format
- Table 5-100 Mode Parameter Block Descriptor-Data Format
- Table 5-101 Mode Parameter Header & Block Descriptor -Field Descriptions
- 5.16 PERSISTENT RESERVATION IN Command (5Eh)
- Table 5-102 PERSISTENT RESERVATION IN Command Descriptor Block-Data Format
- Table 5-103 PERSISTENT RESERVATION IN Command-Field Descriptions
- Table 5-104 Read Keys Parameters-Data Format
- Table 5-105 Read Keys Parameters-Field Descriptions
- Table 5-106 Read Reservations Parameters-Data Format
- Table 5-107 Read Reservations Parameters-Field Descriptions
- Table 5-108 PERSISTENT RESERVATION IN Read Reservations Descriptor-Data Format
- Table 5-109 PERSISTENT RESERVATION IN Read Reservations Descriptor-Field Descriptions
- Table 5-110 Persistent Reservation Type Codes and Their Meanings
- Table 5-111 When Do Conflicts Between Existing Reservations and New Reservations Exist?
- 5.17 PERSISTENT RESERVATION OUT Command (5Fh)
- Table 5-112 PERSISTENT RESERVATION OUT Command Descriptor Block-Data Format
- Table 5-113 PERSISTENT RESERVATION OUT Command-Field Descriptions
- Table 5-114 PERSISTENT RESERVATION OUT Command’s Service Action Descriptions
- Table 5-115 Persistent Reservation Type Codes and Their Meanings
- Table 5-116 PERSISTENT RESERVATION OUT Parameter List-Data Format
- Table 5-117 PERSISTENT RESERVATION OUT Parameter List-Field Descriptions
- Table 5-118 Device Server Interpretation of Service and Scope Value
- 5.18 READ (6) Command (08h)
- Table 5-119 READ (6) Command-Data Format
- Table 5-120 READ (6) Command -Field Descriptions
- 5.19 READ (10) Command (28h)
- Table 5-121 READ (10) Command -Data Format
- Table 5-122 READ (10) Command -Field Descriptions
- 5.20 READ BUFFER Command (3Ch)
- Table 5-123 READ BUFFER Command-Data Format
- Table 5-124 READ BUFFER Command -Field Descriptions
- 5.21 READ CAPACITY Command (25h)
- Table 5-125 READ CAPACITY Command-Data Format
- Table 5-126 READ CAPACITY Command -Field Descriptions
- Table 5-127 READ CAPACITY Returned Data-Data Format
- 5.22 READ DEFECT DATA Command (10) (37h)
- Table 5-128 READ DEFECT DATA (10) Command -Data Format
- Table 5-129 READ DEFECT DATA (10) Command -Field Description
- Table 5-130 Defect Descriptor-Block Format.
- Table 5-131 Defect Descriptor-Bytes From Index Format, or Physical Sector Format
- Table 5-132 Defect List Header -Data Format
- Table 5-133 Defect List Header -Field Descriptions
- 5.23 READ DEFECT DATA Command (12) (B7h)
- Table 5-134 READ DEFECT DATA (12) Command -Data Format
- Table 5-135 READ DEFECT DATA (12) Command-Field Description
- Table 5-136 Defect Descriptor-Block Format
- Table 5-137 Defect Descriptor-Bytes From Index Format, or Physical Sector Format
- Table 5-138 Defect List Header-Data Format
- Table 5-139 Defect List Header -Field Descriptions
- 5.24 READ LONG Command (3Eh)
- Table 5-140 READ LONG Command Descriptor Block-Data Format
- Table 5-141 READ LONG Command Descriptor Block-Field Descriptions
- Table 5-142 READ LONG Command -Returned Data
- 5.25 READ SKIP MASK Command (E8h)
- Table 5-143 READ SKIP MASK Command-Data Format
- Table 5-144 READ SKIP MASK Command-Field Description
- 5.26 REASSIGN BLOCKS Command (07h)
- Table 5-145 REASSIGN BLOCKS Command Descriptor Block-Data Format
- Table 5-146 REASSIGN BLOCKS Defect List Header-Data Format
- Table 5-147 REASSIGN BLOCKS Defect List Header -Field Description
- Table 5-148 REASSIGN BLOCKS Defect Descriptor-Data Format
- 5.27 RECEIVE DIAGNOSTIC RESULTS Command (1Ch)
- Table 5-149 Diagnostic Pages Supported by The Drives
- Table 5-150 RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Data Format
- Table 5-151 RECEIVE DIAGNOSTIC RESULTS Command Descriptor Block-Field Descriptions
- 5.27.1 Supported Diagnostics Pages Page (00h)
- Table 5-152 Supported Diagnostics Pages Page-Data Format
- 5.27.2 Translate Address Page (40h)
- Table 5-153 Translate Address Page-Data Format
- Table 5-154 Translate Address Page-Field Descriptions
- 5.28 RELEASE (6) Command (17h)
- Table 5-155 RELEASE (6) Command Descriptor Block-Data Format
- Table 5-156 RELEASE (6) Command -Field Descriptions
- 5.29 RELEASE (10) Command (57h)
- Table 5-157 RELEASE (10) Command Descriptor Block-Data Format
- Table 5-158 RELEASE (10) Command - Field Descriptions
- 5.30 REPORT DEVICE IDENTIFIER Command (A3h)
- Table 5-159 REPORT DEVICE IDENTIFIER Command Descriptor Block-Data Format
- Table 5-160 REPORT DEVICE IDENTIFIER Command Descriptor Block-Field Descriptions
- Table 5-161 REPORT DEVICE IDENTIFIER Parameter List-Data Format
- Table 5-162 REPORT DEVICE IDENTIFIER Parameter List-Field Descriptions
- 5.31 REPORT LUNS Command (A0h)
- Table 5-163 REPORT LUNS Command Descriptor Block-Data Format
- Table 5-164 REPORT LUNS Command Descriptor Block-Field Description
- Table 5-165 LUN Reporting Parameter List -Data Format
- 5.32 REQUEST SENSE Command (03h)
- Table 5-166 REQUEST SENSE Command Descriptor Block-Data Format
- Table 5-167 REQUEST SENSE Command Descriptor Block-Field Description
- 5.32.1 Sense Data Availability
- 5.32.2 Status Reporting
- 5.32.3 Sense Data Format for Error Code 70h and Error Code 71h
- Table 5-168 Sense Data Format for Error Code 70h or 71h-Data Format
- Table 5-169 Sense Data Fields (Error Code 70h)-Field Descriptions
- Table 5-170 Supported Sense Key s
- Table 5-171 Sense Key Information Field Contents
- Table 5-172 Supported Additional Sense Codes and Sense Code Qualifiers (in Hex)
- Table 5-173 Sense-Key Specific Field Contents
- Table 5-174 ILLEGAL REQUEST Sense Key Field Pointer Bytes\Data Format
- Table 5-175 ILLEGAL REQUEST Sense Key Field Pointer Bytes \Field Descriptions
- Table 5-176 NOT READY Sense Key - Progress Indication Bytes\Data Format
- Table 5-177 NOT READY Sense Key - Progress Indication Bytes\Field Descriptions
- Table 5-178 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count-Data Format
- Table 5-179 MEDIUM ERROR or RECOVERED ERROR Sense Key - Retry Count
- 5.33 RESERVE (6) Command (16h)
- Table 5-180 RESERVE (6) Command Descriptor Block-Data Format
- Table 5-181 RESERVE (6) Command -Field Descriptions
- 5.34 RESERVE (10) Command (56h)
- Table 5-182 RESERVE (10) Command Descriptor Block-Data Format
- Table 5-183 RESERVE (10) Command -Field Descriptions
- Table 5-184 Extent Descriptors-Data Format
- Table 5-185 Reservation Types
- Table 5-186 Parameter List When LongID and Extent Bits = 1-Data Format
- Table 5-187 RESERVE (10) ID Only Parameter List-Data Format
- 5.35 REZERO UNIT Command (01h)
- Table 5-188 REZERO UNIT Command Descriptor Block-Data Format
- 5.36 SEEK (6) Command (0Bh)
- Table 5-189 SEEK (6) Command Descriptor Block-Data Format
- 5.37 SEEK (10) Command (2Bh)
- Table 5-190 SEEK (10) Command Descriptor Block-Data Format
- 5.38 SEND DIAGNOSTIC Command (1Dh)
- Table 5-191 SEND DIAGNOSTIC Command Descriptor Block-Data Format
- Table 5-192 SEND DIAGNOSTIC Command -Field Descriptions
- 5.38.1 Supported Diagnostic Page List
- Table 5-193 Supported Diagnostic Page List -Data Format
- 5.38.2 Translate Address Page
- Table 5-194 Translate Address Page-Data Format
- 5.39 SET DEVICE IDENTIFIER Command (A4h)
- Table 5-195 SET DEVICE IDENTIFIER Command Descriptor Block-Data Format
- Table 5-196 SET DEVICE IDENTIFIER Command Descriptor Block-Field Descriptions
- Table 5-197 SET DEVICE IDENTIFIER Parameter List-Data Format
- Table 5-198 SET DEVICE IDENTIFIER Parameter List-Field Descriptions
- 5.40 START STOP UNIT Command (1Bh)
- Table 5-199 START STOP UNIT Command Descriptor Block-Data Format
- Table 5-200 START STOP UNIT Command-Field Descriptions
- 5.41 SYNCHRONIZE CACHE Command (35h)
- Table 5-201 SYNCHRONIZE CACHE Command Descriptor Block-Data Format
- Table 5-202 SYNCHRONIZE CACHE Command -Field Descriptions
- 5.42 TEST UNIT READY Command (00h)
- Table 5-203 TEST UNIT READY Command Descriptor Block-Data Format
- 5.43 VERIFY Command (2Fh)
- Table 5-204 VERIFY Command Descriptor Block-Data Format
- Table 5-205 VERIFY Command-Field Descriptions
- 5.44 WRITE (6) Command (0Ah)
- Table 5-206 WRITE (6) Command Descriptor Block-Data Format
- Table 5-207 WRITE (6) Command -Field Descriptions
- 5.45 WRITE (10) Command (2Ah)
- Table 5-208 WRITE (10) Command Descriptor Block-Data Format
- Table 5-209 WRITE (10) Command -Field Descriptions
- 5.46 WRITE AND VERIFY Command (2Eh)
- Table 5-210 WRITE AND VERIFY Command Descriptor Block-Data Format
- Table 5-211 WRITE AND VERIFY Command -Field Descriptions
- 5.47 WRITE BUFFER Command (3Bh)
- Table 5-212 WRITE BUFFER Command Descriptor Block-Data Format
- Table 5-213 WRITE BUFFER Command -Field Descriptions
- 5.48 WRITE LONG Command (3Fh)
- Table 5-214 WRITE LONG Command Descriptor Block-Data Format
- Table 5-215 WRITE LONG Command-Field Descriptions
- 5.49 WRITE SAME COMMAND
- Table 5-216 WRITE SAME Command Descriptor Block-Data Format
- Table 5-217 WRITE SAME Field Description
- 5.50 WRITE SKIP MASK Command (EAh)
- Table 5-218 WRITE SKIP MASK Command (EAh)
- Table 5-219 WRITE SKIP MASK Command - Field Description
- Chapter 6 FEATURE DESCRIPTIONS
- 6.1 KEY FEATURES
- 6.2 WRITE-BACK CACHING
- 6.3 ZERO LATENCY READ/WRITE
- 6.4 DISCONNECT-RECONNECT
- 6.5 TRACK AND CYLINDER SKEWING
- 6.6 AVERAGE ACCESS TIME
- 6.7 EMBEDDED SERVO SYSTEM
- 6.8 DATA INTEGRITY AND SECURITY
- 6.8.1 Media Error Protection
- 6.8.2 Transfer Error Protection
- 6.8.3 Addressing Error Protection
- 6.8.4 Data Sector Reallocation Error Protection
- 6.8.5 Data Verification
- 6.9 TAGGED COMMAND QUEUING
- 6.10 COMMAND REORDERING
- 6.11 BANDED RECORDING
- 6.12 DIAGNOSTICS
- 6.12.1 Power On Self Test (POST)
- 6.12.2 Periodic Self-Adjustments
- 6.12.3 Host Diagnostics
- 6.12.4 Log Sense
- 6.13 ERROR RECOVERY
- 6.13.1 Seek Error Recovery
- 6.13.2 Data Read Errors
- 6.13.3 Reallocation of Bad Blocks
- 6.14 THE ULTRA160 and ULTRA320 LOW VOLTAGE DIFFERENTIAL (LVD) SCSI INTERFACE
- 6.14.1 DIFFSENS
- 6.14.2 DIFFSENS SWITCHING
- 6.14.3 DT AND ST CLOCKING
- Figure 6-1 ST and DT CLocking
- 6.14.4 CYCLIC REDUNDANCY CHECKING
- 6.14.5 DOMAIN VALIDATION
- 6.14.6 Adaptive Active Filter (AAF)
- 6.14.7 Transmitter Pre-Compensation with Cutback
- 6.14.8 Free Running Clock (FRC)
- 6.14.9 Skew Compensation
- 6.14.10 Information Unit Transfers
- 6.15 HOT PLUGGING/REMOVAL AND INSERTION OF SCSI DEVICES
- 6.15.1 System Considerations
- 6.15.2 APPLICABLE SCSI PHYSICAL DOCUMENTS
- Appendix A QUICK REFERENCE
- A.1 SCSI-2/SCSI-3 Equivalent Terminology
- Table A-1 SCSI-2/SCSI-3 Equivalent Terminology
- A.2 SCSI Commands and Messages
- Table A-2 SCSI-3 Quick Reference - Commands
- Table A-3 SCSI-3 Quick Reference - Messages
- A.3 SCSI Pages
- Table A-4 SCSI-3 Quick Reference - Pages
- A.4 Sense Keys
- Table A-5 SCSI-3 Quick Reference - Sense Keys
- A.5 Status Codes
- Table A-6 SCSI-3 Quick Reference - Status Codes
- Appendix B NEGOTIATED RATE INFORMATION PAGE REFERENCE
- B.1 TRANSFER PERIOD FACTOR FIELD
- Table B-1 Transfer Period Factor Field Values When PARL = 1
- Table B-2 Transfer Period Factor Field Values When PARL = 0
- B.2 Settings for the QAS, DT, and IU fields
- Table B-3 Settings for the QAS, DT, and IU Fields of the Negotiated Rate Information Page (INQUIRY Command)

Maxtor Atlas 10K V 5-147
5.43 VERIFY Command (2Fh)
The VERIFY command verifies the data on the medium for the Logical Block
Address range specified. The data format and field descriptions are shown in Table 5-
204 and Table 5-205 respectively.
Table 5-204 VERIFY Command Descriptor Block-Data Format
Table 5-205 VERIFY Command-Field Descriptions
Bit
Byte
765 4 3210
0 Operation Code (2Fh)
1 Reserved DPO Reserved BytChk RelAdr
2 - 5 Logical Block Address
6 Reserved
7 - 8 Verification Length
9 Control
Field Description
DPO
Disable Page Out. When the value of the field = 1, the device server will assign the logical
blocks accessed by this command the lowest priority for being fetched into or retained by the
cache.
When DPO = 0, the priority will be determined by fields in the Caching page.
BytChk
Byte Check. When the value is 1, the drive performs a byte-by-byte comparison of the data
on the medium with the data sent by the initiator in the data-out buffer transfer.
When 0, the drive performs a medium verification with no data comparison. In this case, no
data is sent by the initiator.
RelAdr Relative Address. This feature is not supported; the field must be 0.
Logical
Block
Address
The address of the first logical sector to be verified.
Verifica-
tion Length
The number of contiguous sectors that are to be verified. The drive returns a CHECK CON-
DITION status with the correct sense data if the specified transfer extends beyond out of the
logical sector space.