Specifications

6
MaxStream XStream-PKG Wireless Modem Operation Manual
WR 8 Write all configurable parameters to
non-volatile memory. All setable
parameters are stored.
No parameters NA NA
CN 9 Exit AT command mode No parameters NA NA
E0 10 No echo in AT command mode No parameters NA NA
E1 11 Echo characters in AT command mode No parameters NA NA
LH 12 Transmit beacon time Time in tenths of seconds for the wake up
beacon
11
FH 13 Force beacon on next transmit No parameters NA NA
RE 14 Restore defaults configuration No parameters NA NA
ER 15 Set receive error count Value of error count. This value is reset to
0 after every reset it is not non-volatile
20
GD 16 Set receive good count Value of good count. This value is reset to
0 after every reset it is not non-volatile
2 0
HP 17 Set group number. Each radio group uses
a different hop sequence. Seven different
group numbers available.
Number 0 to 6. Use this parameter to
operate independent networks of
XStream radios in the same vicinity.
1 0
MK 18 Set RAD mask (Radio ADdress mask) Address mask. Only bits set to 1 is used
in the address comparision. A global
address is an address that has the same
bits set as the address mask.
2 FFFF
CC 19 Set command sequence character Number for the command character. Valid
from 32 to 127.
1 2B
VR 20 Firmware version Firmware version 2 NA
BD 21 V4.08 Set UART baud rate Number corresponding to UART baud
rate. Baud rate doesn’t take effect until
ATCN command is issued. If the baud
command is issued in binary mode it
must be stored (ATWR) and a new baud
rate will take affect after reset
1 - 2400
2 - 4800
3 - 9600
4 - 19200
5 - 38400
6 - 57600
13
RT 22 V4.10 RTS Control 0 - No binary commands accessed with
RTS
1- Binary commands are sent when RTS
is asserted
10
SY 23 V 4.12 Set sync timer Time in tenths of seconds that the
transmitter and receiver stay in sync after
receiving or sending data. Setting this
parameter to 20 (0x14) will allow any
radio to transmit within the next 2
seconds utilizing a beacon of 8ms instead
of 35ms. Use this parameter to speed up
communication latency and turn-around
time.
10
AT
Command
Binary
Command #
Description Parameters
# Bytes
Returned
For Binary
Factory
Default
Table 4-1. MaxStream Command Table (Continued)