Product manual
XStream‐PKG‐T™TelephoneRFModem–ProductManualv5.x00[2006.02.24]
SL (Serial Number Low) Command
<Diagnostic> Set/Read the serial number low
word of the module.
AT Command: ATSH
Binary Command: 0x26 (38 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
Minimum Firmware Version Required: 4.27C
SM (Sleep Mode) Command
AT Command: ATSM
Binary Command: 0x01
Parameter Range: 0 – 8
Parameter Configuration
0 Disabled
1 Pin Sleep
2 Serial Port Sleep
3
Cyclic 0.5 second sleep
(Module wakes every 0.5
seconds)
4 Cyclic 1.0 second sleep
5 Cyclic 2.0 second sleep
6 Cyclic 4.0 second sleep
7 Cyclic 8.0 second sleep
8 Cyclic 16.0 second sleep
Default Parameter Value: 0
Number of bytes returned: 1
<Sleep Mode (Low Power)> SM Command is
used to adjust Sleep Mode settings. By default,
Sleep Mode is disabled and the module remains
continually active. SM Command allows the
module to run in a lower-power state and be
configured in one of eight settings.
Cyclic Sleep settings wake the module after the
amount of time designated by SM Command. If
the module detects a wake-up initializer during
the time it is awake, it will synchronize with the
transmitter and start receiving data after the
wake-up initializer runs its duration. Otherwise, it
returns to Sleep Mode and continue to cycle in
and out of inactivity until the Wake-up Initializer
is detected. If a Cyclic Sleep setting is chosen,
the ST, LH and HT parameters must also be set
as described in the “Sleep Mode” section of this
manual.
Related Commands:
©2006MaxStream,Inc.,ConfidentialandProprietary 58
Pin Sleep – PC (Power-up Mode), PW (Pin
Wake-up)
Serial Port Sleep – ST (Time before Sleep)
Cyclic Sleep – ST (Time before Sleep), LH
(Wake-up Initializer Timer), HT (Time Before
Wake-up Initializer), PW (Pin Wake-up)
ST (Time before Sleep) Command
<Sleep Mode (Low Power)> ST Command sets
the period of time (in tenths of seconds) in which
the module remains inactive before entering into
Sleep Mode. For example, if the ST Parameter is
set to 0x64 (100 decimal), the module will enter
into Sleep mode after 10 seconds of inactivity (no
transmitting or receiving). This command can
only be used if Cyclic Sleep or Serial Port Sleep
Mode settings have been selected using SM
(Sleep Mode) Command.
AT Command: ATST
Binary Command: 0x02
Parameter Range: 0x10 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0x64 (100 decimal)
Number of bytes returned: 2
Related Commands: SM (Sleep Mode), LH
(Wake-up Initializer Timer), HT (Time before
Wake-up Initializer)
www.agelectronica.com www.agelectronica.com