Sleep Modes and Connections
Cyclic sleep can be used with the remote modems to conserve power. ST “Time before Sleep”
Parameter defines how long after a disconnect a remote will stay awake. A modem is not allowed
to enter sleep mode when it is engaged in a connection. A modem will wake as defined by SM
parameter and check for an RF message. If a message is detected, the modem will stay awake
only if the message is a connect message from the base for this modem. DI3 (pin 2) wake-up can
be used to wake a remote modem. Usually the connection on DI3 should also be enabled so that
a connection is established on wake-up.
NOTE: The ST (Time Before Sleep) time must be set long enough to account for the time it could take
to make a connection if several remote modems get a connection before a remote’s ST times out.
Pin sleep can also be used with a remote modem. A modem will not be allowed into pin sleep
while a connection is active. Usually the connection on DI3 (DR = 4) should also be enabled so
that a connection is established on wakeup. Pin wake-up could also be used to scan for a
connection at an interval not defined by the cyclic sleep modes.
I/O Passing and Connections
I/O lines can be passed between a remote and base modem by enabling I/O line passing (see the
RT, DR, CD, CO, CS, BK, BO commands). When a connection is not active, the output lines on the
base and remote modems will be in their default state. When a connection is established, the
base and remote output line will be set to reflect the corresponding input lines.
Monitoring Connections
The DO3 pin (RX LED) can be used to show when a connection is active on both remote and base
modems. This is the default condition. This line will be asserted (high) during a connection and
de-asserted (low) when there is no connection.
A base modem can also be set to send the “CONNECT XXXX” string (where “XXXX” is the
connecting modem’s MY (Source Address) parameter) anytime a connection is established. Refer
to CM (Connection Message) Command.