Product manual
XStream‐PKG‐T™TelephoneRFModem–ProductManualv5.x00[2006.02.24]
Table3‐03. TelephoneModuleATCommands–AmpersandCommands
(Low‐assertedsignalsaredistinguishedbyhorizontallineoverpinname.)
AT
Command
Parameters
Ampersand (&) Commands
&Cn
n = 0
Always On
n = 1 Module Controls
(default)
&Dn
n = 0 Ignore
n = 1
drop puts module in command mode without disconnecting
n = 2
drop causes the module to hang up (default)
n = 3
drop causes module to perform a soft reset as if the Z command were received
&Fn
n = 0 Restore Factory Configuration 0
n = 1 Restore Factory Configuration 1
&Gn
n = 0 No Guard Tone (default)
n = 2 1800 Hz Guard Tone
&Kn
n = 0 Disables flow control
n = 3 Enables
/ hardware flow control (default)
n = 4 Enables XON/XOFF software flow control
n = 5 Enables transparent XON/XOFF software flow control
&Rn
n = 0
follows . - delay set by “S26” S-Parameter.
n = 1
always asserted.
&Sn
n = 0
Always On (default)
n = 1 Module Controls
&Tn
n = 0 Terminates test in progress
n = 1 Begin Analog Loopback Test
&V Diagnostic command - Reports current configuration, stored user profiles and first 4 stored telephone numbers
&V1 Diagnostic command - Shows statistics for most recent connection
&Wn
n = 0 Store configuration as profile 0
n = 1 Store configuration as profile 1
&Yn
n = 0 Hard reset restores profile 0
n = 1 Hard reset restores profile 1
&Zn Stores telephone number dial string (to 31 digits) into n (n = 0 - 3)
S-Parameters
Reading and Setting S-Parameters
Commands that begin with the letter “S” are called S-Parameters. The number following the “S”
indicates the parameter number. The Telephone Module can select an active S-Parameter and
(where applicable) perform read/write operations. Commands can be performed on an S-
Parameter as follows:
ATSn – Makes S-Parameter n active
ATSn=v – Sets S-Parameter n to value v
ATSn? – Reads current value of S-Parameter n
Once a register is made active (the last register accessed), the register name is optional and can
be omitted from subsequent read/write commands that reference the same register. This is show
in the table below.
Table3‐04. Samplereadandwritecommandsusingactiveregister
Command System Response
ATS7 Make “S7” Parameter Active
AT=51 or ATS7=51 Set “S7” to 51 (decimal)
AT? Read Value of “S7”
If the number n (or the value v on a write) is out of range or invalid, the module will return the
“ERROR” message. All S-Parameter values and responses are in decimal format. All S-Parameters
can be read using “&V” command [Table 3-03].