XStream-PKG-E™ Ethernet RF Modem XStream Ethernet RF Modem Operation RF Modem Configuration Appendices Product Manual v4.2A XStream RF Modem Part Numbers: X09-001PK…-E… X24-009PK…-E... X09-009PK…-E… X24-019PK…-E… XH9-009PK…-E... X09-019PK…-E… 355 South 520 West, Suite 180 Lindon, UT 84042 Phone: (801) 765-9885 Fax: (801) 765-9895 rf-xperts@maxstream.net www.maxstream.net (live chat support) M100110 10.27.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A © 2004 MaxStream, Inc. All rights reserved No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of MaxStream, Inc. XStream™ is a registered trademark of MaxStream, Inc. XPort is a trademark of Lantronix. Ethernet is a trademark of XEROX Corporation. Technical Support: Phone: (801) 765-9885 Live Chat: www.maxstream.net E-Mail: rf-xperts@maxstream.net © 2004 MaxStream, Inc.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A XStream Ethernet RF Modem XStream-PKG-E Ethernet RF Modems extend system performance and flexibility by adding serial connectivity to Ethernet networks. MaxStream RF Modems handle the complexities inherent to RF communications (modulation, demodulation, frequency synthesizers, amplifiers, filters, FCC approvals, etc.), so OEMs and integrators can focus resources beyond the wireless portion of the data system.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A XStream-PKG-E Interface Front and Back Views 1a. Figure 1. Power Switch Move Power Switch to the ON (up) position to power the XStream PKG-E Ethernet RF Modem. Front View 1b. I/O & Power LEDs LEDs indicate modem activity as follows: Yellow (top LED) = Green (middle) = Red (bottom) = when powered, pulses 1d.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A XStream-PKG-E Ethernet RF Modem Specifications Table 1. XStream-PKG-E Ethernet RF Modem (900 MHz & 2.4 GHz) Specifications Specification 9XStream-PKG-E (900 MHz) 24XStream-PKG-E (2.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A RF Operation Data Radio System Components XStream Radio Modems are designed to provide long range wireless links between devices in a data system. The PKG-E Ethernet RF Modem connects serial modems to Ethernet networks.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Communications The Ethernet-connected serial modem supports several connection options: • Com Port Redirector Software enables legacy serial applications to communicate with the Ethernet RF Modem by forwarding serial data over Ethernet. • “Telnet” communicates directly to the Ethernet RF Modem using port 14001. Refer to the “Telnet Loopback Test” section on page 11 for an example that by-passes the com port.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Setup Com Port & IP Address The XStream-PKG-E Ethernet RF Modem supports DHCP (Dynamic Host Configuration Protocol) and Auto IP protocols. Both protocols automatically assign IP addresses to nodes of a network. Ethernet RF Modem Discovery The X-CTU Software provides an easy-to-use interface that searches a local network and then displays Ethernet RF Modems found. Discover Ethernet RF Modem, Map Com Port & Assign IP Address: 1.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Assign Static IP Address To assign a static IP address to the Ethernet RF Modem, follow the steps outlined below. A static IP address may be necessary when: • The Ethernet RF Modem and the host PC are on different subnets • The Ethernet RF Modem IP address might be changed by a DHCP server Configure a static IP address on a local network: 1.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Testing Communications When testing a wireless link, MaxStream suggests creating the link using the following components: • XStream-PKG-E Ethernet RF Modem (connected to a local network) • XStream-PKG-R RS-232/485 RF Modem (w/ loopback adapter) • PC (connected to a local network) • Peripherals (Loopback adapter, CAT5 UTP cable, power supplies and RPSMA antennas) Hardware Setup for Loopback Test: 1.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Telnet Loopback Test MaxStream Wireless links can be tested by connecting to the specific IP address and port number. Test a Wireless Link (Telnet Connection): 1. Follow steps in the “XStream-PKG-E Ethernet RF Modem Discovery” section [page 8]. 2. Setup hardware as shown in the ‘Hardware Setup for Loopback Test’ section of previous page [Figure 8]. 3.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A RF Modem Configuration Out-of-box, the XStream-PKG-E Ethernet RF Modem comes configured to provide an immediate wireless link between devices in a data system. The default configuration supports a wide range of RF communications. The RF modem is configurable to support specific system requirements using standard AT Commands.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A AT Commands AT Commands can be used to adjust several modem characteristics: • AT Command Mode Options • Diagnostics • Networking • Serial Interfacing • Sleep (Low Power) A terminal program has been built into the X-CTU software and is located under the “Terminal” tab. Use the following syntax when using terminal software to issue AT Commands. Figure 12.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Configuration MaxStream provides the X-CTU Software for configuring the PKG-E Ethernet RF Modem. Other programs such as “Telnet” can also be used to establish communications. Local Network Method 1. Install both the X-CTU Software and the Ethernet Com Port Redirector [See “Com Port Communications” [page 7] section for more information]. 2.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A XStream Commands (Short View) Table 2. XStream AT Commands as of Firmware Version 4.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Appendix A: Agency Certifications FCC Compliance The MaxStream XStream-PKG-E Ethernet RF Modem has been tested and certified to comply with Part 15 of the FCC Rules. In order to inherit MaxStream’s FCC Certification, compliance requires the following be stated: FCC ID: OUR9XSTREAM (for 900 MHz) or OUR-24XSTREAM (for 2.4 GHz) This device complies with Part 15 of the FCC Rules.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A FCC Notices Adherence to the following is required: IMPORTANT: The 9XStream (900 MHz) and 24XStream (2.4 GHz) OEM Modules have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Changes or modifications not expressly approved by MaxStream could void the user’s authority to operate the equipment.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A 9XStream-PKG-E (900 MHz) Approved Antenna List Table 3. XStream-PKG-E 900 MHz Approved Antennas with Separation Distances compliant with FCC Exposure Requirements Manufacturer 900 MHz Part Number Type Gain Application Minimum Separation Distance * * Yagi 6.2 dBi Fixed/Mobile ** 20 cm * * Yagi 7.2 dBi Fixed/Mobile ** 20 cm MaxStream A09-Y8 Yagi 8.2 dBi Fixed/Mobile ** 20 cm * * Yagi 9.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A 24XStream-PKG-E (2.4 GHz) Approved Antenna List Table 4. XStream-PKG-E 2.4 GHz Approved Antennas with Separation Distances compliant with FCC Exposure Requirements * Manufacturer 2.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A European Compliance (2.4 GHz only) The 24XStream has been certified for several European countries. For a complete list, go to www.maxstream.net. If the 24XStream modules are incorporated into a product, the manufacturer must ensure compliance of the final product to the European harmonized EMC and low-voltage/safety standards.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Important Note MaxStream does not list the entire set of requirements that must be met for each country. MaxStream customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Appendix B: Additional Information 1-Year Warranty The XStream-PKG-E Ethernet RF Modem from MaxStream, Inc. (the ʺProductʺ) is warranted against defects in materials and workmanship under normal use, for a period of 1-year from the date of purchase. In the event of a product failure due to materials or workmanship, MaxStream will repair or replace the defective product.
XStream-PKG-E™ Ethernet RF Modem – Product Manual v4.2A Ethernet Background Information Ethernet Port (RJ-45) Pin Signals The MaxStream Ethernet RF Modem uses standard Ethernet protocol. Figure 19. Ethernet Pinout Diagrams Networking Terms DHCP: Dynamic Host Configuration Protocol - A protocol for automated assigning of dynamic IP addresses to devices on a network. DHCP allows IP addresses to be pooled and assigned as needed to clients.