Product manual
XStream‐PKG‐R™RS‐232/485RFModem–ProductManualv4.2B
©2005MaxStream,Inc.Confidential&Proprietary 40
Notifications and Required Information
Since the 2.4 GHz band is not harmonized throughout Europe, a notification must be sent to each
country prior to shipping product according to Article 6.4 of the R&TTE Directive. A list of
national contacts for most European countries may be found at www.ero.dk/.
The following technical data (relating to the 24XStream) is often required in filling out a
notification form.
• Frequency Band: 2400.0 – 2483.5 MHz
• Modulation: Frequency Shift Keying
• Channel Spacing: 400 kHz
• ITU Classification: 400KF1D
• Output Power: 100 mW EIRP
• Notified Body Number: 0891
Contact MaxStream (801) 765-9885 if additional information is required.
Europe (2.4 GHz) Approved Antenna List
TableA.3. Antennasapprovedforusewith24XStream(2.4GHz)RFModemsinEurope
Manufacturer Part Number Type Gain Application
Minimum Separation
Distance
MaxStream A24-HABMM-P6I Dipole 2.1 dBi Fixed/Mobile * 20cm
MaxStream A24-HBMM-P6I Dipole 2.1 dBi Fixed/Mobile * 20cm
MaxStream A24-HABSM Dipole 2.1 dBi Fixed/Mobile * 20cm
MaxStream A24-QABMM-P6I Monopole 1.9 dBi Fixed/Mobile * 20cm
MaxStream A24-QBMM-P6I Monopole 1.9 dBi Fixed/Mobile * 20cm
MaxStream A24-Q1 Monopole 1.9 dBi Fixed/Mobile * 20cm
*CanbeapprovedforportableapplicationsifintegratorgainsapprovalthroughSARtesting
IC (Industry Canada) Certification
Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label
on the outside of the final product enclosure must display the following text:
Contains Model 9XStream Radio (900 MHz), IC: 4214A-9XSTREAM
Contains Model 24XStream Radio (2.4 GHz), IC: 4214A 12008
Integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B -
Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada
accepts FCC test report or CISPR 22 test report for compliance with ICES-003.