Emergency shutdown control
through EPO allows users to shut
down the UPS completely in an
emergency to ensure a safe operating
environment.
Communication software allows
not only the control of the UPS and its
smooth shutdown when Utility fails,
but also allows the user to
Completely test the major operating
functions of the UPS
Communicate via SNMP/Web/
Network adapter
Access UPS functions via the Web
and also
Alert users via SMS messages
against specifi c events
Custom options slot allows further
exibility in network confi guration.
An internal WEB/SNMP card, AS/400
card, USB card and True Relay card
provide isolated contacts for industrial
and remote alarm panel application.
User-friendly Plug-and-Play design
allows hassle-free installation. All units
up to 3kVA are supplied with input
cables and output receptacles as
standard.
Innovative battery management
circuit analyzes battery discharging
status to adjust battery cut-off point
and extend the batteries’ life span.
Internal maintenance-free sealed-
type battery minimizes the need for
frequent after-sales service. The hot
swappable battery feature can enable
users to replace the batteries without
the hazard of electric shock, while
the UPS supplies power continuously
to critical load applications.
Built-in Charger provides ability
to re-charge internal battery to
approximately 90% in four hours.
Matching battery cabinets are available
to extend the UPS runtime easily to
several hours.
Optional extended runtime
capability by simply connecting
additional battery packs. Just plug in
the battery connectors between the
UPS and battery packs without the
requirement for additional chargers.
Extended run time battery packs
are available for all models. Size,
capacity and estimated run times
are shown in the table below. Back
up time is for the battery pack used
with the UPS internal batteries.
Battery packs are external and hot
swappable.
Optional Make-Before-Break
Bypass Switch—manually operated,
external—ensures continuous supply
of power to the critical load in the
event of unexpected or scheduled
maintenance.
Battery Run Time Chart (shown in minutes)
UPS
Size
Part
Number
Quantity 25%
Load
50%
Load
75%
Load
100%
Load
H x W x D (inches)
Weight
(lbs. each)
I kVA Internal 0 50 20 10 7 N/A N/A
USC-BP1K 1 380 160 95 66 3.5" x 17.3" x 25.6" 83
2 740 320 195 130 3.5" x 17.3" x 25.6" 83
3 1150 505 310 215 3.5" x 17.3" x 25.6" 83
4 1575 695 430 300 3.5" x 17.3" x 25.6" 83
2kVA Internal 0 45 18 10 7 N/A N/A
USC-BP3K 1 195 80 45 33 3.5" x 17.3" x 25.6" 87
2 320 155 95 66 3.5" x 17.3" x 25.6" 87
3 550 240 145 100 3.5" x 17.3" x 25.6" 87
4 745 325 195 135 3.5" x 17.3" x 25.6" 87
3kVA Internal 0 40 15 8 5 N/A N/A
USC-BP3K 1 163 65 40 25 3.5" x 17.3" x 25.6" 87
2 305 130 75 53 3.5" x 17.3" x 25.6" 87
3 460 195 120 80 3.5" x 17.3" x 25.6" 87
4 650 280 170 120 3.5" x 17.3" x 25.6" 87
Notes: Battery rated at 12V; 1/2k
VA 7A/hour, 3kVA 9A/hour, 1kVA 36V, 2/3kVA, 72V
Optional Maintenance Bypass
Model Number Rating/Voltage Input Connection Output Receptacles
USC-MBPDU-11RT 1kVA / 120V Attached 6' Cord with 5-15P (8) 5-15R
USC-MBPDU-21RT 2kVA / 120V Attached 6' Cord with 5-20P (6) 5-15R & (2) 5-20R
USC-MBPDU-31RT 3kVA / 120V Attached 6' Cord with L5-30P (4) 5-15R & (1) 5-30R
USC-MBPDU-12RT 1kVA & 2kVA / 230V Attached 6' Cord with IEC C14 (8) IEC C13
USC-MBPDU-32RT 3kVA / 230V Attached 6' Cord with IEC C20 (6) IEC C13 & (1) IEC C18
Dimensions: 3.5" H (2U) x 17.3"W x 3.0"D