Manual
Electrical Data
UPS Power (kVA)
65 80 100 125 160 200 250
Standards
●
Underwriters Laboratories, Listed to
UL1778 (Designed to 60950);
c-UL to CSA C22.2
●
CE
●
NEMA PE-1
●
ASME
●
ASA-C-39.1-1984
●
FCC PT 15, Subpart J, Class B
●
National Electrical Code
●
OSHA
●
IEEE 587 ANSI C 62.41-1980
●
ISO 9001
●
IBC (International Building Code)
Ratings A-F, Site Specifi c
FirstLine P 80, 100, 125kVA Part Numbers
Model kVA / kW Voltage
FLU-65-00 65VA/58.5kW 480V - 480Y/277
FLU-80-00 80kVA/72kW 480V - 480Y/277
FLU-100-00 100kVA/90kW 480V - 480Y/277
FLU-125-00 125kVA/112.5kW 480V - 480Y/277
FLU-160-00 160kVA/144kW 480V - 480Y/277
FLU-200-00 200kVA/180kW 480V - 480Y/277
FLU-250-00 250kVA/225kW 480V - 480Y/277
BY-PASS
Nominal voltage 480Vac 3-phase (with or without neutral)
Nominal voltage tolerance
± 15% (can be regulated from ± 10% to ± 25%
from the control panel)
±20% (can be regulated from ±5% to ±25%
from the control panel)
Nominal frequency 60 Hz
Frequency tolerance ± 2% (can be regulated up to ± 6% from the control panel)
Switching time inverter-by-pass with Inverter
synchronized (UPS Normal)
Approx. 0ms
Switching time inverter-by-pass with
non-synchronized Inverter (UPS in “Normal Mode”)
20ms
(Can be calibrated from 10 to 100 ms or with inhibition of
transfer onto bypass)
Switching time from by-pass to Inverter
(Stand-by / On Mode)
from 2 to 5ms
Delay in transferring to Inverter after the switching
onto by-pass
4 sec
Overload Capacity of by-pass line (kVA) 125 % for 60 minutes, 150 % for 10 minutes 110% for 60 min., 125% for 10 min.
Short circuit capacity of by-pass line (x nominal
current)
1 second
500 ms
200 ms
100ms
10ms
65
20
23
26
30
40
80
15
18
21
22
30
100
12
15
17
18
25
125
10
12
14
15
20
160
9
10
11
12
18
200
7
8
9
10
14
250
9
10
11
12
18
SYSTEM
On-Line AC/AC effi ciency
• Full load
• Load 50%
93 %
93.5 %
93.5%
94%
94%
94.5%
Effi ciency with UPS in STAND-BY mode 98 %
Full Load Heat Rejection BTU/hr 15,033 18,500 23,120 28,900 36,880 46,230 57,780
Maximum current dispersion 300mA maximum
MECHANICAL
Dimensions – inches
UPS Power (kVA)
65 80 100 125 160 200 250
Height x Width x Depth – inches (mm) 75 (1900) x 31.5 (800) x 33.5 (850) 75 (1900) x 39 (1000) x 33.5 (822)
Weight – lbs. / Kg 1,213 / 550 1,213 / 550 1,433 / 650 1,544 / 700 1984 / 900 2,205 / 1000 2,425 / 1100
Freestanding NEMA 1 enclosure, powder coat painted black color with textured fi nish, bottom access for conduit entries
ENVIRONMENTAL
Ambient temperature 0° C to 40° C
Storage temperature -25° C to 70° C
Relative humidity 20 – 90% non-condensing
Altitude 3,281 feet without derating
Audible noise 65 dBA @ 1 meter 68 dBA @ 1 meter