Installation Notes

TROUBLESHOOTING
07
During usage, the heater may be unable to start normally,
or may flame-out soon after startup, leading to a locked
malfunction state. In such cases, try to restart the heater:
turn it off, keep it shut down for at least 3 seconds, then
start it again.
Circuit malfunction can occur for various reasons, such
as: corrosion (of connectors, wires, fuse, battery poles),
poor connector contact, incorrectly connected wires, etc.
Users must pay attention to inspection and maintenance
to prevent such problems.
7.1 Solutions for Common Problems
PARKING AIR HEATER
33
7.2 Fault Codes
In case of a fault, a fault code and corresponding faulty component icon will flash on the LCD panel. Please refer to the following
fault code and solutions table to resolve the problem.
A flashing glow plug, oil pump, fan, sensor, or power supply icon indicates a fault in the corresponding device.
PARKING AIR HEATER
34
UndervoltageE-1
OvervoltageE-2
Fault code Cause of failure Solutions
1. confirm that power supply voltage matches heater voltage, normalranges: 12V(9-16V) or 24V(18-32V);
2. confirm that power cord is properly installed;
3. confirm that additional non-compliant power cord is not in use;
4. confirm that power converter can provide sufficient current;
5. confirm that power converter output voltage is stable;
6. confirm thatfusehas notdeteriorated.
1. confirm that voltage of the power supply matches the voltage of the heater, normalrange: 12V(9-16V)/24V
(18-32V);
2. confirm that power cord is properly installed;
3. confirm that additional non-compliant power cord is not in use;
4. confirm that power converter can provide sufficient current;
5. confirm that power converter output voltage is stable;
6. confirm thatfusehas notdeteriorated.
1. confirm thattheheatingductisnot blocked;
2. confirm thatthefanisworkingproperly;
3. confirm thatthetemperaturesensorisoperating normally.
Glow plug failure
E-3
E-4
1.1 confirm that ignitionplugconnectorisnot looseand that wirehas notshort-circuitedtohousing;
1.2 confirm thatignitionplugisnot damaged;
2.1 appearance of this code immediately after start-up represents a mainboard fault; the mainboard
will need to be replaced;
2.2 appearance of this code after start-up and about 15 seconds of fan operation represents a glow plug
fault; the glow plug will need to be replaced;
2.3 appearance of this code about 50 seconds after start-up represents an installation problem; please
check the power supply voltage.
Hightemperature Alarm :
intake> 50
case>270