The heater must be checked carefully before use, ensuring
that there are no leaks and that all connections are in safe
conditions. If dense smoke, fuel smells or irregular noise
become apparent, the heater must be shut down and the
fuse removed. The heater must only be put back into use
after repair by a qualified professional.
8.1 Check Before Use
PARKING AIR HEATER
35
Fan motor faultE-5
Flameout
E-6
Fault code Cause of failure Solutions
1.confirm thatthefan wheelisnot stuck;
2.confirm thattheconnectoris plugged insecurely;
3.confirm thatgapbetweenthe wheelmagnetandcontroller’s Hallsensoris not excessive;
4.confirm thatthepower lineis notin a short-circuitoropen-circuit state;
5.Electric leakage.
1. confirmadequate fuel,and absence of lowtemperaturesolidificationoffuel orother blockageinfuel
pipeline andfuel pump;
2. Confirm thatintakeandexhaustductsarenot blocked;
3. confirm thathousingtemperaturesensorisin completecontactwiththehousing,and thepressurespring
isapplying adequate pressure.
1.confirm that the fuel has not run out;
2.confirm that the fuel pipelines are not frozen or blocked;
3.confirm that the fuel pump is operating normally:
3.1 confirm that there is no air trapped in the fuel line causing discontinuous fuel supply;
3.2 confirm that the fuel is of adequate quality;
3.3 refer to fault code E-8 for other pointers.
1.sensor connectors are damaged or have loosened;
2.sensor is damaged.
Unsuccessfulstart up
E-8
1. large amount of whitesmokeinexhaustgasses:
1. 1 confirm thatfilternet besideplug glowis clean, if not, clean or replace it;
1.2 confirm thatfuelinjectioniseffective;
1.3 confirm thatglow plughas not deteriorated;
1.4 confirm thatfan wheelblows normally;
1.5 blow some fresh air into the heater via air inlet pipe.
2. smallamountofwhitesmokeinexhaustgasses, ornosmoke:
2.1 confirm that fuel has not run out;
2.2 confirm that fuel pipelines are not frozen or blocked;
2.3 confirm thatpumpisnot blockedordamaged;
2.4 confirm that intake and exhaust pipe are not blocked;
2.5 confirm that glow plug is not damaged;
3. ignition is normal but ignition failure fault is reported:
3.1 confirm that housingtemperaturesensorisinfull contactwithhousing,thatpressurespringisstrong,and
that sensoris operating normally;
3.2 confirm that excessive carbon deposition has not occurred, if so this must be cleaned.
Flameout twice
E-9
Sensor fault