Specifications
68 MaxPac Single/Dual/Triple-Screen 8230 Training and Maintenance Guide
Figure 5-9
Figure 5-10
5) Press down on the release catch holding the power cable and gently pull this connector away
from this display (Figure 5-10).
6) Observe the cable tie attaching the power and data cables to a standoff post mounted to the right
of the screen assembly. Cut or remove this cable tie as needed (Figure 5-11).
Figure 5-11
Figure 5-12
7) Open the right-hand screen to a vertical position, use a Phillips #2 screwdriver to remove the
eight 6-32 1/4" black countersunk screws – four on each site – holding the screen to its hinge bar
(similar to the procedure for the left-hand screen as shown in Figure 5-6), and then lift the screen
away (Figure 5-12).
8) Perform the above steps in reverse order to replace the failed screen with the new unit as
supplied by MaxVision support.
Flat Panel Display Module (Center Screen)
1) Lay the system flat on the table with the displays in the closed position and facing upwards (it is
recommended that you lay the system on bubble wrap in order to protect the finish). If your
MaxPac system has three screens, unfold the left- and right-hand screens as shown in Figure
5-13 (if your MaxPac system has only two screens, unfold the right-hand screen.)