Specifications
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
84
PATENTS PENDING
OVERLOAD ERRORS
Overload Error code readings are not displayed
when the Controller is in diagnostic mode. They
are only displayed on the Controller when an
Overload Error occurs while operating the Lift.
Each function of the Lift is assigned a limit on
how much electrical current it can draw. If the
electrical current goes over the limit, the Control-
ler stops the Lift to prevent damage. Then the
Controller reading will show which Lift function
was operating at the time of the overload. The
Controller reading will fl ash between ERROR:
OVERLOAD! (FIG. 84-1) and an 11-digit code
(i.e. 00100000000) (see FIG. 84-2 & TABLE
84-1). A “1” in the output code means that a
specifi c function was on when the overload oc-
curred, and “0” means that a specifi c function
was off when the overload occurred.
ERROR OVERLOAD CODE
(EXAMPLE OVERLOAD SHOWN FOR RAISE FUNCTION)
TABLE 84-1
ERROR OVERLOAD CODE
READINGS ON THE CONTROLLER
00 1 0 0 0 0 0 0 0 0
NOT USED
NOT USED
RAISE
LOWER
FOLD
UNFOLD
VISUAL
AUDIO
PLATFORM LIGHTS
EXTRA OUTPUT
UNLATCH
CODE DIGITS
LIFT FUNCTIONS
ERROR: OVERLOAD!
EXAMPLE CONTROLLER
ERROR CODE READING
FIG. 84-1
EXAMPLE CONTROLLER
ERROR CODE READING
FIG. 84-2
00100000000