Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
81
PATENTS PENDING
POSITION CODE FUNCTION
1 1 or 0 Outboard Switch (1 open/Outboard Rollstop not up,
0/closed Outboard Rollstop up)
2 1 or 0 Inboard Switch (1 open/ 0 closed)
3 1 or 0 Lowering Switch (1 open/below oor level, 0 closed at
or above oor level)
4 1 or 0 Stow Switch (1 open/not stowed, 0 closed/stowed)
5 1 or 0 UNFOLD Button (1 open/not pressed, 0 closed/button
pressed)
6 1 or 0 FOLD Button (1 open/not pressed, 0 closed/button
pressed)
7 1 or 0 DOWN Button (1 open/not pressed, 0 closed/button
pressed)
8 1 or 0 UP Button (1 open/not pressed, 0 closed/button
pressed)
STATUS READINGS FOR SECOND SET OF CODES
TABLE 81-1
4. Status display of 2nd set of switches:
The reading for the second set of 8 switches
is in binary code (i.e. 00001111) (FIGS. 81-
1 and 81-2). Read the status from left to
right for the second set of 8 binary codes
(TABLE 81-1).
DOWN 00001111
EXAMPLE CONTROLLER
DIAGNOSTIC READING
FIG. 81-1
HAND CONTROL
FIG. 81-3
UP
FOLD
UNFOLD
DOWN
5. Use the second set of codes to check the
Hand Control (FIG. 81-3). The 4 but-
tons on the Hand Control can be checked
individually. When displaying the second
set of binary codes, press each of the 4
buttons to see if the status of the buttons
changes from “1” to “0”. If one button does
not change code, trace the function for that
button. If none of the 4 buttons change
code, then the Hand Control or the con-
necting wiring harness is bad.
00001111
12345678
CODES FOR SECOND SET OF SWITCHES
FIG. 81-2
CODE DIGITS