Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
80
PATENTS PENDING
3. Status display of rst set of switches:
The reading for the rst set of 8 switches is
in binary code (i.e. 11110101) (FIGS. 80-
1 and 80-2). Read the status from left to
right for the rst set of 8 binary codes. A “1”
means open and “0” is closed. The rst 4
of 8 status numbers will always read 1 (i.e.
11110101) (TABLE 80-1).
11110101
12345678
CODE DIGITS
CODES FOR FIRST SET OF SWITCHES
FIG. 80-2
POSITION CODE FUNCTION
1 Always 1 Not in Use (extra switch)
2 Always 1 Not in Use (extra switch)
3 Always 1 Not in Use (extra switch)
4 Always 1 Not in Use (extra switch)
5 1 or 0 Ground Switch (1 open/ground level, 0 closed/above
ground level)
6 1 or 0 Mat Switch (1 open/no pressure, 0 closed/pressure)
7 1 or 0 Folding Switch (1 open/at or below oor level, 0
closed/above oor level)
8 1 or 0 Seat Belt Switch (1 open/engaged, 0 closed/disen-
gaged)
STATUS READINGS FOR FIRST SET OF CODES
TABLE 80-1
DOWN 11110101
EXAMPLE CONTROLLER
DIAGNOSTIC READING
FIG. 80-1
DIAGNOSTIC MODE - Continued