Specifications
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
16
PATENTS PENDING
LH SIDE OF LIFT
FIG. 16-1A
ADJUSTING SWITCH
FIG. 16-1B
THRESHHOLD
PLATE
THRESHOLD
WARNING BEACON
4. Turn the MAT switch adjustment screw
(FIGS. 16-1B and FIG. 16-2) clockwise
until Threshold Warning Alarm and Beacons
are activated (FIG. 16-1A). Then turn
adjustment screw counter-clockwise (FIG.
16-2) approximately 1-1/2 turn. Warning
Alarm and Beacons should turn off.
5. Step on Threshhold Plate. Warning Alarm
and Beacons should activate. If the Warn-
ing Alarm and Beacons do not activate, turn
Adjustment Screw (FIG. 16-1B) clockwise
(FIG. 16-2) a little. Repeat until Warning
Alarm and Beacons activate when you step
on Threshhold Plate and turn off when you
step off Threshhold Plate.
MAT SWITCH ADJUSTMENT SCREWS
FIG. 16-2
CW - UNTIL ALARM &
BEACONS TURN ON
1-1/2 TURN CCW - ALARM
& BEACONS TURN OFF
BASE
PLATE
ADJUSTMENT
SCREW
THRESHOLD
WARNING ALARM
MAT SWITCH ADJUSTMENT - Continued