Service manual

Operating Manual SL6000 Series
Page 10 of 27
Cloning
The SL6402 radio requires the cloning cable. The frequencies and functions can be
programmed from radio to radio by using a cloning cable.
Ensure that both radio’s power is in the switched “OFF” position.
Place the master radio (the radio which already has desired program information in the
EEPROM) in the data master mode by holding the radio’s monitor switch and then turning
radio power switch to the “ON” position (the red LED on the radio flashes). Release the
monitor switch on the third led flash (the radio will display “MASTER” message on the
LCD).
Place the slave radio (the radio which is not programmed, or has program information that
will be erased) into data slave mode by holding the radio’s monitor switch and then turning
the radio power switch to the “ON” position (the red LED on the radio flashes). Release
the monitor switch on the second led flash (the radio will display “SLAVE” message on the
LCD).
Connect the cloning cable through accessory socket.
Press the slave radio’s monitor switch. The LED will glow green.
Press the master radio’s monitor switch. The LED will glow red and cloning will start.
After cloning, the slave radio displays "COMPLETED" message and the master radio
displays “MASTER” message on LCD.
For cloning other radios, repeat above procedure.
Cloning set-up (Fig.2)
Master PK-SL6000-02 cloning lead Slave
C
C
C
l
l
l
o
o
o
n
n
n
i
i
i
n
n
n
g
g
g