Specifications

8
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
Check for rust and oily surfaces on Liftgate. If there is rust or oil on the Liftgate, clean it off.
Touch up the paint where bare metal is showing.
Damaged cylinder seals and contaminated hydraulic uid can result from paint-
ing the polished portion of the cylinder rod. To prevent damage, protect the
exposed polished portion of the cylinder rod while painting.
CAUTION
PERIODIC MAINTENANCE
PERIODIC MAINTENANCE CHECKLIST
Visually check the entire Liftgate for excessively worn parts and broken welds, especially
the Hinge Pins. See PARTS BREAKDOWN section for replacement parts. With the Cylin-
der Housing Cover removed, lubricate drive chains with red grease. Also, do the Semi-an-
nual and Quarterly Maintenance checks.
Annually or 5000 Cycles (whichever occurs rst)
Quarterly or 1250 Cycles (whichever occurs rst)
Semi-annually or 2500 Cycles (whichever occurs rst)
Visually check the Platform Hinge Pins for excessive wear and broken welds. See PARTS
BREAKDOWN section for replacement parts. Also, do the Quarterly Maintenance checks.
Never operate the Liftgate if parts
are loose or missing.
WARNING
If Hydraulic Fluid appears contaminated, refer to the CHANGING HYDRAULIC FLUID
procedure in the PERIODIC MAINTENANCE section.
Check the Hydraulic Fluid level in the Pump Reservoir. Refer to the CHECKING HYDRAU-
LIC FLUID procedure in the PERIODIC MAINTENANCE section.
Keep track of the grade of Hydraulic Fluid in the Pump Reservoir and never mix two differ-
ent grades of uid.
Check all Hoses and Fittings for chaf ng and uid leaks. Replace if necessary.
Check electrical wiring for chaf ng and make sure wiring connections are tight and free of
corrosion.
Check that all WARNING and instruction decals are in place and legible.
Check that all roll pins are in place and protrude evenly from both sides of Hinge Pin collar.
Replace roll pins if necessary.
!