CHECKING HYDRAULIC FLUID
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydrau-
lic lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
+50 to +120 Degrees F - Grade ISO 32
Below + 70 Degrees F - Grade ISO 15 or MIL-H-5606
NOTE: Use correct grade of hydraulic fl uid for your location.
See TABLES 38-1 and 38-2 for recommended brands.
1. Open and lower platform to ground level.
Unfasten latch and remove the pump cover
(FIG. 37-1) .
CHECKING FLUID LEVEL
FIG. 37-2
3. Reinstall fi ller cap (FIG. 37-2).
2. Remove threaded fi ller cap (FIG. 37-2).
Check the hydraulic fl uid level in reservoir.
Hydraulic fl uid level should be 1” below
the top of fi ller hole (FIG. 37-2). If needed,
add hydraulic fl uid to fi ll the reservoir to the
level shown in FIG. 37-2.
FILLER CAP
RESERVOIR
4. Reinstall the pump cover and fasten
latch (FIG. 37-2).
1”
CAUTION
Pump Cover must be correctly secured
to prevent it from becoming a hazard.
To secure Pump Cover, fasten the rub-
ber latch on the Pump Box to the re-
ceiver on the Pump Box Cover.
LATCH
PUMP COVER
REMOVING / REINSTALLING
PUMP COVER
FIG. 37-1