Installation manual

33
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
CONNECT POWER CABLE TO BATTERY
3. Reconnect power to Liftgate by
reconnecting negative (-) cable
to (-) negative post on battery
(FIG. 33-3).
NOTE: MAXON recommends using dielectric grease on all electrical connections.
1. Disconnect power from Liftgate by
disconnecting negative (-) cable
from negative (-) post on battery
(FIG. 33-1).
WARNING
!
To prevent accidental personal injury
and equipment damage, make sure
power is disconnected from Liftgate
while installing parts.
DISCONNECTING BATTERY
FIG. 33-1
NEGATIVE (-)
POST
NEGATIVE (-)
BATTERY CABLE
RECONNECTING BATTERY
FIG. 33-3
NEGATIVE (-)
POST
NEGATIVE (-)
BATTERY CABLE
2. Remove nut from positive (+) battery
terminal connector. Connect power
cable to the positive (+) battery terminal
connector (FIG. 33-2). Re-install and
tighten nut.
NUT
CONNECTING POWER CABLE
FIG. 33-2
POSITIVE (+)
BATTERY TERMINAL
FUSED
POWER CABLE
BOLT