Installation manual

22
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
ATTACH OPTIONAL BATTERY BOX & FRAME TO
VEHICLE (IF EQUIPPED) - Continued
4. Connect battery cables, fused
cables, and ground cables as
shown in FIG. 22-1.
NOTE: Always connect fused end of power cable to battery positive (+) terminal.
NOTE: To connect charge lines, refer to instructions provided with each charge
line kit.
FUSED CABLE
(SEE NOTE)
(-) BATTERY CABLE
TO COMMON
GROUND
(FUSED CABLE TO
PUMP BOX)
(IN PARTS BOX)
42” LG.
CIRCUIT
BREAKER
CABLE
18” LG.
CABLE
10” LG.
(GROUND CABLE
TO PUMP BOX OR COMMON
CHASSIS GROUND)
74” LG.
NOTE: MAXON recommends using dielectric grease on all electrical connections.
12 VOLT BATTERY CONNECTIONS
ELECTRICAL COMPONENTS - BATTERY BOX
FIG. 22-1
Remove all rings, watches and jewelry before doing any electrical work.
WARNING
!