11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
12 VOLT BATTERY CONNECTIONS
FIG. 39-2
(-) BATTERY
CABLES
150 AMP CIRCUIT
BREAKER
(+)
BATTERY
CABLES
POWER CABLE
TO PUMP BOX
3. Recommended battery box
setup for 12 volt batteries is
shown in FIG. 39-2.
200 AMP FUSED POWER CABLE
(ONLY IF REQUIRED - SEE NOTE)
150 AMP CIRCUIT BREAKER
(NEAR TRUCK OR
TRACTOR BATTERY AND/OR
NOSE OF TRAILER)
CHARGE LINE TO
TRUCK OR TRACTOR
BATTERY
(-) BATTERY
CABLE
6 VOLT BATTERY CONNECTIONS
FIG. 39-1
150 AMP CIRCUIT
BREAKER
(+)
BATTERY
CABLES
POWER CABLE
TO PUMP BOX
200 AMP FUSED POWER CABLE
(ONLY IF REQUIRED - SEE NOTE)
2. Recommended battery box
setup for 6 volt batteries is
shown in FIG. 39-1.
CHARGE LINE TO
TRUCK OR TRACTOR
BATTERY
NOTE: Always connect fused end of power cable to battery positive (+) terminal.
150 AMP CIRCUIT BREAKER
(NEAR TRUCK OR
TRACTOR BATTERY AND/OR
NOSE OF TRAILER)
RECOMMENDED LIFTGATE POWER CONFIGURATION - Continued