Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
95
FIG. 95-1
LOWER PORT
RAISE PORT
5. Check the hydraulic cylinder. With the platform at
vehicle oor level, remove the hydraulic line from
the LOWER port on the cylinder (FIG. 95-1).
Hold the control switch in the “RAISE” position for
two seconds while you watch for hydraulic uid at
the LOWER port. A few drops of hydraulic uid es-
caping the port is normal. However, if uid streams
out, piston seals are worn. Replace seals.
6. If pump cannot produce 3200 PSI or
lift the load capacity with a minimum of
12.6 volts available, the pump is worn
and needs to be replaced.