Specifications

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
88
PLATFORM WILL NOT RAISE & MOTOR WILL NOT RUN
TROUBLESHOOTING
TERMINAL “A”
LOAD
TERMINAL “B”
BATTERY (+)
TERMINAL “D”
SWITCHED BATTERY (+)
STARTER
SOLENOID
TERMINAL “C”
GROUND (-)
2. Touch a jumper wire to terminals “B” & “D” (FIG. 88-1).
If motor runs, check control switch, the switch connections,
and white wire. Check and correct wiring connections or
replace the control switch.
3. Touch heavy jumper cables to terminals “A” & “B”
(FIG. 88-1).
a. If motor runs, replace the motor solenoid.
b. If motor does not run, repair or replace the pump motor.
1. Connect voltmeter between motor so-
lenoid terminal “B” and ground wires
connection on pump (FIG. 88-1). Verify
that full battery voltage is at “B”. Re-
charge the battery if voltmeter indicates
less than 12.6 volts dc.
GRAVITY DOWN POWER UNIT
FIG. 88-1