Owner`s manual

28
Date: 7.5.2012
Version: 1.00
P7000-K Owners Manual
LED indications:
The STATUS LED will indicate several different conditions of the Trail Charger. This is accomplished by the use of a Bi-
Color LED that will indicate with either a solid color or a blinking color at three different blink rates, see table below:
RATE
TIMING
Slow
1 second on, 1 second off
Medium
500ms on, 500 ms off
High
250ms on, 250ms off
Definition of indications is found in the following table:
INDICATION
STATUS
Fault Condition
Input Command
Reduce
Shutdown
Reduce
LED off
Module off, ignition or input voltage not
present.
-
-
-
RED, blink, high-rate
FAULT, any on the fault list, which follows
this table.
Any Fault condition
-
-
Green, blink, medium
SHUTDOWN mode
No Faults
ON
-
Green, blink, slow
Reduce power mode, charging.
No Faults
OFF
ON
Green, solid
Charging or Charged.
No Faults
OFF
OFF
A RED LED blinking at a high rate indicates one of the following fault conditions exist:
• Input over-voltage limit.
• Input under-voltage limit.
• Output over-voltage limit.
• Output over-current limit.
• Output FET’s over thermal limits.
A fast blinking RED from any fault indication has a higher priority than all other indications if the ignition is on.
Temperature Compensation (The output is temperature compensated to provide a higher voltage level at lower
temperatures as recommended by AGM battery manufacturers.)