FUNCTIONAL DESCRIPTION
STB: Switch to battery. An STB input gets connected to a positive voltage source to activate its function.
STG: Switch To Ground. An STG input gets connected to ground in order to activate its function. Connections to the unit
are made via a 4-pin Deutsch connector and a 6 pin Deutsch connector.
The terminals are as follows:
Conn - Pin
Name
Notes:
J1-1
Vin
Provides the input voltage to the converter.
J1-2
Vout
Output to the battery to be charged. Keep wiring as short as possible.
J1-3
Ground
System ground. Must be common to both input and output.
J1-4
Ignition
STB Input. Enables the converter when Ignition is on.
J2-1
Reduce
STB input. When J2-1 is ³3Vdc, the current available to Vout (J1-2) is limited to
approximately 12A.
J2-2
Shutdown
STB input. When J2-2 is ³ 3, J1-2, Vout is disabled and will not charge a battery.
J2-3
N/A
Programming pin, factory use only. Do Not Connect.
J2-4
GLED
Connects to the green LED positive terminal. (external LED1)
J2-5
RLED
Connects to the red LED positive terminal. (External LED1)
J2-6
Reduce
STG input. When J2-6 is ²3Vdc, the current available to Vout (J1-2) is limited to
approximately 12A.