Specifications
Control Valves - SMARTLINK
®
MRV
www.maxoncorp.com
combustion systems for industry
Maxon reserves the right to alter specifications and data without prior notice.
© 2014 Copyright Maxon Corporation. All rights reserved.
10-30.7-85
E-i -3/14
50120624-001/
Table 15: SMARTLINK
®
MRV User Display Command Summary
Note 1: Press [MENU] key to move down Main Menu or Sub-Menu list.
Note 2: Press [BACK] key to move up Main Menu or Sub-Menu list.
Note 3: Press [ENTER] to move from Main Menu to Sub-Menu list.
Note 4: Press [BACK] keys to move from top command item in Sub-Menu back to the Main Menu.
Note 5: Press [ENTER], [BACK], or [ARROW] keys to accomplish specific Sub-Menu tasks as prompted by the display.
Note 6: When on a Main Menu item, press [MENU] and [DOWN] key simultaneously to reach last Main Menu item.
Note 7: When on a Main Menu item, press [BACK] and [UP] key simultaneously to reach first Main Menu item.
Table 15: SMARTLINK
®
MRV User Display Command Summary
MAIN & SUB-MENU ITEMS
(See Notes 1-7 below)
MENU & SUB-MENU DESCRIPTIONS
Main
Menu #
Sub
Menu #
Menu Item Descriptions
1
SMARTLINK MRV Status
Or
More Status [ENTER]
View mode of operation, firing rate or startup state, and alarm status
Or
Enter status sub-menu to view additional status
1.1
1.2
1.3
1.4
1.5
Ctl Interface Status
Valve #0 Status
Valve #1 Status
Valve #2 Status
Valve #3 Status
Control Interface commissioning status, S/W version, and ID number
Valve #0 position status, S/W version, and ID number
Valve #1 position status, S/W version, and ID number
Valve #2 position status, S/W version, and ID number
Valve #3 position status, S/W version, and ID number
2
Manual Mode [ENTER] Execute Command A-0: Enter Manual Positioning Mode
2.1
2.2
2.3
2.4
2.5
2.6
2.7
Maximum Fire
Minimum Fire
Set Index
Set Valve #
Move FR 10%
Move FR 1%
Run Mode
[ENTER]
[ENTER]
[ARROWS]
[ARROWS]
[ARROWS]
[ARROWS]
[ENTER]
Move valves synchronously to maximum position index (#9)
Move valves synchronously to minimum position index (#0)
Move valves synchronously to selected position index
(Command A-3) Select valve for viewing positions
Change firing rate by 10% up or down
Change firing rate by 1% up or down
Exit manual mode and resume control via 4-20 mA firing rate input
3
Set Max & Ramp [ENTER] Execute Command A-5: Set Max Position & Min/Max Ramp
3.1
3.2
3.3
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
[ARROWS]
[ARROWS]
[ARROWS]
(Command A-3) Select valve for adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile
4
Set Min & Ramp [ENTER] Execute Command A-6: Set Min Position & Min/Max Ramp
4.1
4.2
4.3
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
[ARROWS]
[ARROWS]
[ARROWS]
Select valve for adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile
5
Setup Mode [ENTER] Execute Command A-2: Enter Position Setup Mode
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
Set Index
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
Set Valve #
Set Fluid
Commission
Run Mode
Save Backup
Load Backup
Load Default
[ARROWS]
[ARROWS]
[ARROWS]
[ARROWS]
[ARROWS]
[ARROWS]
[ENTER]
[ENTER]
[ENTER]
[ENTER]
[ENTER]
Move valves synchronously to selected position index
(Command A-3) Select valve for profile adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile
(Command A-3) Select valve for profile adjustment
Set fluid type for selected valve
(Command A-4) Commission Valve; [ARROWS] select valve
Exit Position Setup Mode and return to RUN mode
(Command C-6) Save Profile as Backup
(Command C-7) Restore Profile from Backup
(Command C-3) Reset Factory Default Settings
6
Set Standby [ENTER] Execute Command B-2: Set Standby Position
6.1
6.2
6.3
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
[ARROWS]
[ARROWS]
[ARROWS]
(Command A-3) Select valve for profile adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile
7
Set Purge [ENTER] Execute Command B-1: Set Purge Position
7.1
7.2
7.3
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
[ARROWS]
[ARROWS]
[ARROWS]
(Command A-3) Select valve for profile adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile
8
Set Lightoff [ENTER] Execute Command B-5: Set Light-Off Position
8.1
8.2
8.3
Set Valve #
Trim 1.0 deg
Trim 0.1 deg
[ARROWS]
[ARROWS]
[ARROWS]
(Command A-3) Select valve for profile adjustment
Adjust selected valve in 1.0 degree steps; [ENTER] to save profile
Adjust selected valve in 0.1 degree steps; [ENTER] to save profile