Installation guide
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
40
HYDRAULIC SCHEMATIC
SYSTEM DIAGRAMS - Continued
FIG. 40-1
M
LOCK VALVES
CYLINDERS
HYDRAULIC
MOTOR
LOCK
CYLINDER
FLOW CONTROL
VALVE (4 GPM)
VALVE
S3
PRV
2250 PSI
PRV
1015 PSI
VALVE
S1
VALVE
S2
P
(TEST PORT)
A
(OPEN)
B
(CLOSE)
NOTE: PRV (PRESSURE RELIEF VALVE)
PRV
1015 PSI
FILTER
FILTER
PUMP
RESERVOIR
CHECK
VALVE
CHECK
VALVE
CHECK
VALVE
CHECK
VALVE
FLOW
CONTROL
VALVE (2 GPM)
FLOW
CONTROL
VALVE (2 GPM)