Datasheet

Setup
Generally applicable Rules
maxon motor control
ESCON Servo Controller Document ID: rel5869
3-11
ESCON 36/2 DC Hardware Reference Edition: November 2015
© 2015 maxon motor. Subject to change without prior notice.
3Setup
IMPORTANT NOTICE: PREREQUISITES FOR PERMISSION TO COMMENCE INSTALLATION
The ESCON 36/2 DC is considered as partly completed machinery according to EU Directive 2006/42/
EC, Article 2, Clause (g) and is intended to be incorporated into or assembled with other machin-
ery or other partly completed machinery or equipment.
3.1 Generally applicable Rules
For each possible motor variant you will find information on the from/to connections and the cables you
will require. If you should decide not to use the ready-made maxon cables, you must establish the
respective connections as to chapter “3.4.7 ESCON 36/2 DC Connector Set” on page 3-29 and
chapter “4 Wiring” on page 4-33.
Maximal permitted Supply Voltage
Make sure that supply power is between 10…36 VDC.
Supply voltages above 38 VDC, or wrong polarity will destroy the unit.
Note that the necessary output current is depending on the load torque. Yet, the output current limits
of the ESCON 36/2 DC are as follows; continuous max. 2 A / short-time (acceleration) max. 4 A.
How to read the Wiring Details
The subsequent description follows this scheme:
Column “J… & Head A”: Pin number…
– of the socket,
– of the corresponding plug, and
– of Head A of the matching prefab maxon cable.
Column “Prefab Cable”: Wire color of the prefab maxon cable.
Column “Head B”: Pin number of Head B of the matching prefab maxon cable.
WARNING
Risk of Injury
Operating the device without the full compliance of the surrounding system with EU Directive
2006/42/EC may cause serious injuries!
Do not operate the device, unless you have made completely sure that the other machinery fully
complies with the EU directive’s requirements!
Do not operate the device, unless the other machinery fulfills all relevant health and safety
aspects!
Do not operate the device, unless all respective interfaces have been established and fulfill the
requirements stated in this document!