User's Manual
FCC Documentation- CM-5100P CDMA 1X Network card
8/25
Maxon Proprietary : Restricted Distribution. This document is the sole and exclusive property of Maxon
Australia. Not to be distributed or divulged without prior written agreement.
Maxon Electronics Australia Pty. Ltd. 36A Gibson Avenue, Padstow, N.S.W. Australia
Tel : +61 2 9707-2000 Facsimile : +61 2 9707-3328 URL : http//www.maxon.com.au
3.4.2 Receiver specifications
Table 2.5 Receiver performance
Type of Receiving Super Heterodyne Method
Frequency Range 869.94MHz ~ 893.37MHz
Channel Number 20CH
Band width 1.23MHz
Type of Oscillation PLL Synthesizer & VCTCXO(19.2MHz)
VCO Output Frequency Range
( divide-by-2 frequency range)
1372.08MHz ~ 1419.54MHz
(686.04MHz ~ 709.77MHz)
Intermediate Center Frequency 183.6MHz
Modulation Method QPSK
Receiver Sensitivity Under -104dBm @FER=0.5%
Single Tone Desensitization
(-30dBm @F
C
+/-900KHz)
Under -101dBm @FER=1%
-43dBm Under -101dBm @FER=1%
-32dBm Under -90dBm @FER=1%
Inter-modulation
(Fc +/-900KHz&1.7MHz)
-21dBm Under -79dBm @FER=1%
Common RF Impedance 50ohm
Supplied voltage +3.0V DC