Installation Sheet
© Copyright 2017. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 800-555-5629 Fax: 973-244-7333 Email: info@maxlite.com
Installation & Operation
1.) Please prepare one piece metal conduit
and 5pcs wires when replacing the lamps
and lanterns.
Operating Instructions ECO Series
MaxLite ECO Series 6” & 8” Commercial Downlight Retrofit
®
2.) Turn off electrical power before removing the
CFL lampand trim.
3-1.) Open driver box cover.
Page: 2
REV: 5/17/17
3-2.) Insert metal conduit at driver J-box. Connect
conduit wires with corresponding driver wires
and add a quick connector to the black (LED-)
and red (LED+) driver wires. (See wiring
diagram).
3-3.) Close the driver cover.
LED Lamp Replacement Marking - Identifying the replacement LED lamp type/model to be used along with
manufacturer and ordering information.
Marquage de remplacement de la lampe - Identification du type / modèle de lampe LED de remplacement à
utiliser avec le fabricant et les informations de commande
Models:
RRECO612ZZ@/V2 – 120-277V 50/60 Hz RRECO818ZZ@/V2 – 120-277V 50/60 Hz
RRECO618ZZ@/V2 – 120-277V 50/60 Hz RRECO824ZZ@/V2 – 120-277V 50/60 Hz
RRECO627ZZ@/V2 – 120-277V 50/60 Hz RRECO840ZZ@/V2 – 120-277V 50/60 Hz
RRECO812ZZ@/V2 – 120-277V 50/60 Hz
Model options: ZZ = CCT (Color Temperature) / @ = Trim Color (White or Silver
)