Specification Sheet

Phone: 1-800-555-5629 | Fax: 973-244-7333 | Web: www.maxlite.com | E-mail: info@maxlite.com
MAX16067
Revised: 04/26/18
Page: 3 of 3
LED STRIP
LS SERIES
I – Disable
II – 50Lux
III – 10Lux
IV – 2Lux
I – 0s
II – 10s
III – 1min
IV – 5min
V – 10min
VI 30min
VII 1H
VIII
This is the time period you would like to keep at the low light output
level before it is completely switched o in the long absence of people.
This is the dimmed low light output level you would like to have after
the hold-time in the absence of people.
Stand-by period (corridor function)
3
Stand-by dimming level
4
5%
10%
20%
30%
Disable
50Lux
10Lux
2Lux
0s
10s
1min
5min
10min
30min
1H
+
“Daylight” : The lamp works always,even during daylight.
Twilight” : The lamp works only in twilight and in darkness.
“Darkness” : The lamp works only in darkness.
I – 5%
II – 10%
III – 20%
IV – 30%
application.
Daylight sensor
5
Operating voltage
Switched power (capacitive load)
Stand-by power
Detection area
Hold-time
Stand-by period
Stand-by dimming level
Daylight threshold
Sensor principle
Microwave frequency
Microwave power
Detection range
Detection angle
Mounting height
Operating temperature
120~277VAC
400W@120VAC; 800W@230VAC; 1000W@277VAC
<1W
10%/50%/75%/100% (100% /50% /10% on RC)
5s/30s/1min/5min/10min/20min/30min (TEST 2s/30s/1min/5min/10min/30min on RC)
0s/10s/1min/5min/10min/30min/1h/+∞ ( 0s /10s / 1min / 10min/ 30min /+ on RC)
5%/10%/20%/30% (10%/20%/30% on RC)
2~50Lux/disable (2Lux /10Lux / 50Lux /Lux disable on RC)
High frequency (microwave)
5.8GHz+/-75MHz
0.2mW
Max. (OxH): 8m x 5m
30
o
~150
o
Max. 5m
-20
o
C ~ +60
o
C
Technical Data
Semko, CB, EMC, CE, R&TTE, SAA
+
Note: “0s means on/o control;
daylight sensor is disabled.
8
I – 100%
II – 75%
III 50%
IV 10%
Detection area can be reduced by selecting the combination on the
I – 5s
II – 30s
III – 1min
IV 5min
V 10min
VI 20min
VII 30min
Hold-time means the time period to keep the lamp on 100%, after all
motion has ceased (detection area vacated).
Hold-time
Detection area
1
2
100%
75%
50%
10%
5s
30s
1min
5min
10min
20min
30min
Below are all available settings for the MSC option. Purchase of the remote
control (RMHYTHRC-05) is required in order to change factory settings.
Ceiling mounted height (Ft)
10%
10%
30%
30%
75%
75%
50%
50%
16Ft
13Ft
Ceiling mounted detection pattern (Ft)
HRC-05
Stand-by dimming level
Detection range
ON/
OFF
Auto Mode
Reset
Power
80%
Test
2s
10%
20%
30s 1min
100%
30min10min5min
0s 10s 1min
30%
SC1 SC2
SC3
Scene mode
10min
50% 10%
30min
Hold-time
Stand-by period
5min
Lux
Disable
2Lux
10Lux
50Lux
Daylight Sensor
SC4
Power
100%
+
-
Dim
M/A
Remote control (RMHYTHRC-05)
I – Disable
II – 50Lux
III – 10Lux
IV – 2Lux
I – 0s
II – 10s
III – 1min
IV – 5min
V – 10min
VI 30min
VII 1H
VIII
This is the time period you would like to keep at the low light output
level before it is completely switched o in the long absence of people.
This is the dimmed low light output level you would like to have after
the hold-time in the absence of people.
Stand-by period (corridor function)
3
Stand-by dimming level
4
5%
10%
20%
30%
Disable
50Lux
10Lux
2Lux
0s
10s
1min
5min
10min
30min
1H
+
“Daylight” : The lamp works always,even during daylight.
Twilight” : The lamp works only in twilight and in darkness.
“Darkness” : The lamp works only in darkness.
I – 5%
II – 10%
III – 20%
IV – 30%
application.
Daylight sensor
5
Operating voltage
Switched power (capacitive load)
Stand-by power
Detection area
Hold-time
Stand-by period
Stand-by dimming level
Daylight threshold
Sensor principle
Microwave frequency
Microwave power
Detection range
Detection angle
Mounting height
Operating temperature
120~277VAC
400W@120VAC; 800W@230VAC; 1000W@277VAC
<1W
10%/50%/75%/100% (100% /50% /10% on RC)
5s/30s/1min/5min/10min/20min/30min (TEST 2s/30s/1min/5min/10min/30min on RC)
0s/10s/1min/5min/10min/30min/1h/+∞ ( 0s /10s / 1min / 10min/ 30min /+ on RC)
5%/10%/20%/30% (10%/20%/30% on RC)
2~50Lux/disable (2Lux /10Lux / 50Lux /Lux disable on RC)
High frequency (microwave)
5.8GHz+/-75MHz
0.2mW
Max. (OxH): 8m x 5m
30
o
~150
o
Max. 5m
-20
o
C ~ +60
o
C
Technical Data
Semko, CB, EMC, CE, R&TTE, SAA
+
Note: “0s means on/o control;
daylight sensor is disabled.
8
I – 100%
II – 75%
III 50%
IV 10%
Detection area can be reduced by selecting the combination on the
I – 5s
II – 30s
III – 1min
IV 5min
V 10min
VI 20min
VII 30min
Hold-time means the time period to keep the lamp on 100%, after all
motion has ceased (detection area vacated).
Hold-time
Detection area
1
2
100%
75%
50%
10%
5s
30s
1min
5min
10min
20min
30min
Below are all available settings for the MSC option. Purchase of the remote
control (RMHYTHRC-05) is required in order to change factory settings.
MS