Remark
Disarm
Send this
operation code
from your cell
phone
SMS reply you
will receive
1234#0
Arm
1234#1
1234#2
__
__
43
__
1234#91
1234#90
Electrical
Facility
AC
Wired Accessories:
It supports 2 groups of wired accessories.
Please choose the wired sensor types after connected.
Connect Wired Sensor to Wired Zone 1
Connect N.C. Type Door Sensor to Wired Zone. One cable for the IN1
or IN2 block, another for GND block.
Send text 74 to choose wired sensor type to be N.C.
Test if the alarm occurs when wired sensor is trigger.
Connect Wired Siren
Connect the Negative Pole to GND block,
the Positive Pole to N.O block.
Then link COM block and +12V block.
Linkage AC Electronic Facilities:
It is able to turn on electronic facilities like
lights, or fences to deter the intruder
immediately in the event of alarm.
Ground
Power Output for
Wired Accessories
Normal Close
Normal Open
Common Port
Ground
Wired Interface 2
Wired Interface 1
Note!Wired accessories need DC 12V power support.
They can't be used when only with built-in battery.