Brochure

2
© 2011 Maxitrol Company, All Rights Reserved
Mixing Tubes: (and sensor)
Lengths:
MT1-9 or 2-9............................9”
MT1-12 or 2-12.....................12”
MT1-23 or 2-23.....................23”
MT1-28 or 2-28.....................28”
MT1-57...................................57”
Valves
Pipe Sizes:
M411........................... 3/8” & 1/2”
M511...........................1/2” & 3/4”
M611...........................3/4” & 1”
MR212D............1”, 1-1/4”, 1-1/2”
MR212E.....................1-1/2” & 2”
MR212G.....................2-1/2” & 3”
MR212J.......................4” Flanged
MR212-2D, E, G, J ..........(used
for 2-speed blower or dual fuel
operation)
NOTE: M (Modulator) valve
requires a pressure regulator for
high re setting. MR (Modulator-
Regulator) valve requires no
pressure regulator up to 5 psi.
(See Bulletin MMR_MT_EN).
OPTIONAL SYSTEM COMPONENTS
Dual Temperature Selector
DOOR HEATERS: TD114HD use w/TS114 (door closed 55° to 90°F/
open 90° to 140°F)
PAINT SPRAY BOOTHS OR OTHER DUAL APPLICATIONS:
TD214__ (dual selector w/switch - any comb. of 2 standard ranges avail.)
Example 1- TD214G (55° to 90°F [spray] and 90° to 140°F [dry], use w/TS214G
Example 2 - TD214AD (80° to 130°F and 200° to 250°F, use w/TS214AD
TD214__X (same as TD214__, less enclosure)
Inlet Air Temperature Sensors: use with Mixing Tube
TS10765A (8:1 ratio); TS10765B (5:1 ratio); TS10765C (3.5:1 ratio)
Override Stat: (use only with TD114, F ,-1, A-1)
T115 (40° to 90°F)
Series 14 Basic System Options
Valves
Amplier or
Amplier-Selector
Selection
Method
Remote Selector Model
(if applicable)
Sensor Override Stat
Inlet Air
Sensor
M411, M511,
M611,
MR212D, E,
G, or J
(see pg. 4)
A1014R
Single Remote TD114 TS114/ MT1 or 2 T115 TS10765
Dual Remote
TD114HD TS114/ MT1 or 2
__ __
TD214 TS214/ MT1 or 2
Single Integral __ TS114/ MT1 or 2 __ TS10765
AD1214 Dual Integral __ TS214/ MT1 or 2 __ __
MAKE UP AIR APPLICATIONS - Series 14 System
NOTE: Selector and sensor must have the same temperature range to be compatible.
SYSTEM COMPONENTS
Amplier
A1014R
Dual Temperature Amplier-Selectors: (AD1214 shown)
AD1214__ (integral dual selector - any
comb. of 2 standard ranges avail.)
Example1 - AD1214BC (120° to 170°F
and 160° to 210°F), use w/TS214BC
Example2 - AD1214AD (80° to 130°F
and 200° to 250°F), use w/TS214AD
Remote Temperature Selectors
TD114 (55° to 90°F w/override 0° to 40°
over set point)
TD114A (80° to 130°F)
TD114A-1 (80° to 130°F w/ override 0° to
40°F over set point)
TD114B (120 to 170°F)
TD114C (160° to 210°F)
TD114D (200° to 250°F)
TD114E (100° to 250°F)
TD114F (40° to 80°F w/override 0° to 40° over set point)
TD114G (90° to 140°F)
TD114-1 (55° to 90°F w/120° to 170°F override) * use w/TS114
TD114-2 (55° to 90°F w/two outputs)
TD114G-2 (90° to 140°F w/two outputs)
NOTE: Remote Selector and Discharge Temperature Sensor must have
same temperature range to be compatible.
Optional: ETD-1 enclosure, EFP-1 cover plate only - no enclosure
Discharge Air Temperature Sensors: use with Mixing Tube
TS114 (55° to 90°F)
TS114A (80° to 130°F)
TS114B (120° to 170°F)
TS114C (160° to 210°F)
TS114D (200° to 250°F)
TS114E (100° to 250°F)
TS114F (40° to 80°F)
TS114G (90° to 140°F)
TS114J (110° to 160°F) To be used w/ AD1014-1116
TS214__ (dual sensor - any combination of 2 standard ranges available)
Example 1 - TS214G (55° to 90°F and 90° to 140°F, use w/TD114 & TD114G,
or TD214G [selector w/switch], or AD1214G)
Example 2- TS214AD (80° to 130°F and 200° to 250°F, use w/TD114A &
TD114D, or TD214AD [selector w/ switch], or AD1214AD)