64
Pipe Sizes ....................................... 1/2” to 2” threaded connections with NPT or ISO7-1 threads.
Housing Material ........................... GF40, GF60, GF80: aluminum.
Mounting ....................................... Suitable for multi-positional mounting, preferably with lid facing down or to the side to
facilitate removal of debris during maintenance.
NOTE: All Maxitrol gas lters should be installed and operated in accordance
with Maxitrol Safety Warning Instructions (see GF_IO_EN.DE).
Certications ................................... According to DIN 3386, Gas Appliances 2009/142/EC and Pressure Equipment Directive
97/23/EEC.
Gas Types ....................................... Suitable for natural, manufactured, mixed gases, liqueed petroleum gases, LP gas-air
mixtures, sewer gas, and air.
Pressure Tap Connector .................. Optional: Pressure tap (PF10) connections inlet and/or outlet side.
Maximum Inlet Pressure ................ 15 psi (400 kPa)
Ambient Temperature Ranges ......... -4 to 175°F (-20 to 80°C)
Storage and Transport Temp ........... -58 to 175°F (-50 to 80°C)
Filter Replacement ........................ GF40 Models: part number 101706-1
GF60 Models: part number 101706-2
GF80 Models: part number 101706-3
Gas and air lters protect downstream controls (regulators,
automatic shut-off valves) from particulate contamination.
Recommended for use upstream of ttings, regulators, and
controls. Applications for the residential, commercial cooking,
process heating, and industrial burner industries.
GF60
GF SERIES
Gas and Air Filters
Specications