User Guide
F/C Mode
This feature sets the control to operate in either the Fahrenheit (F) or
Celsius (C) mode.
NOTE: Changing between Fahrenheit and Celsius will reset the control to
factory default settings.
Software Version
Displays the version of software utilized by the controller.
Process Identier Menu
Process Ident
This feature allows the user to customize the identication of each process
in a program. The identiers are selected from the following list.
Process Identiers™
Default Cure 3 High Spray 4
Bake Cure 4 Preheat Stage 1
Bake 1 Dry Prep Stage 2
Bake 2 Dry 1 Purge Stage 3
Bake 3 Dry 2 Purge 1 Stage 4
Bake 4 Dry 3 Purge 2 Stage 5
Cool down Dry 4 Purge 3 Stage 6
Cook Hold Spray Stage 7
Cure Idle Spray 1 Stage 8
Cure 1 Low Spray 2 Warm-up
Cure 2 Med Spray 3
Other Features
Process Indication Output
The TM02 multifunctional timer control features a Process Indication
Output. Processes 1 thru 7 have a dedicated pair of terminals, labeled
1 thru 7 on the TM02. An indicator (LED, relay coil, etc...) 24 VDC 2 W
maximum can be wired directly to the corresponding terminal block for
each Process to be indicated.
NOTE: Process #8 does not have a dedicated process indication output.
Program Indication Output
Terminal #8 is used to indicate the controller is operating within a Program.
The following voltage will be measured across the #8 terminals:
Controller in the “READY” position
Controller operating in any of the 8 processes making up a Program
0 VDC
24 VDC 2W max
Features
8