User Guide
Monitor
The Monitor feature is a useful tool when setting up or troubleshooting
the MP2 system. The following will appear on the display when Monitor
is in the “On” position:
Looping Mode (TM02 applications only)
The looping mode feature is used to select the controllers default position
on startup and after the last process of a program is completed.
Selecting “READY”
Power up:
“READY” is displayed. Requires a momentary switch closure
to move the controller to the rst process.
After last, manual process of a program:
After momentary switch closure to move out of the last process,
controller defaults to the “READY” position.
After last, timed process of a program expires:
Controller defaults to the “READY” position.
Selecting “First Process”
Power up:
Controller begins operating in the First Process of the program.
After last, manual process of a program:
After momentary switch closure to move out of the last process,
controller defaults to the First Process.
After last, timed process of a program expires:
Controller defaults to the First Process.
Features
Process #
Set Point Temperature
Manual or Timed
Soft Start
Ramp
Sensed
Process
Temperature
Bandwidth
VDC to Modulator
7