Programming the MP2
Programming
To enter the Process, Operation, Diagnostic, and Process
Identier Menus
Press
PGM
once.
Process Menu programming:
1 Scroll to the Process Menu, press
ENT
.
Process Temperatures
2 Scroll to Temperatures, press
ENT
.
3 Temp Set Point Process #, scroll to Set Point #, press
ENT
.
4 Set Point Temp Process #, XX°F, set Process Temperature
value (OFF, 60°F (15°C) to 240°F (115°C)), press
ENT
.
5 **Stored** will ash 4 times to conrm entry.
6 Repeat steps 2 through 5 for Set Points #(2 - 8).
NOTE: Process #1 CAN NOT be OFF. For unused Process Temperature
Set Points, press down arrow until “Off” is displayed. Set Points #(2 - 8)
are factory set to “Off.”
Process Times (TM02 required)
2 Scroll
to Times and press
ENT
.
Each Process can be either Timed or Manual.
3 Time Process #, scroll to Set Point #, press
ENT
.
MANUAL will be the default.
4 Scroll to Seconds, Minutes or Hours, press
ENT
.
a Set Seconds, Minutes or Hours value with ,
press
ENT
.
b **Stored** will ash 4 times to conrm entry.
c Repeat steps 4 through 4b for each time segment.
for Manual (untimed) Processes
d Default setting or when programmed to 00:00:00.
5 Repeat steps 2 through 4 for Set Points #(2 - 8).
© Copyright 2007, Maxitrol Company. All Rights Reserved.