Installation Guide

Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) Installation Guide - 7 -
Power Supply Board Stand-by Battery Specifications:
Altronix
Model:
Power Supply Board Battery
20 Min. of
Backup
4 hr. of
Backup
24 hr. of
Backup
Maximal3
AL600XB220
(Refer to Fig. 1a, pg. 7 for Switch
[SW1] location and position)
12VDC/40AH* N/A 5.0A N/A
24VDC/40AH* N/A 5.4A 0.7A
Maximal5
AL1012XB220
(Factory set at 12VDC)
12VDC/12AH 9.0A
Battery capacity
for emergency
stand-by:
at least 20 min.
N/A
Maximal7
AL1024XB2V
(Factory set at 24VDC)
24VDC/12AH 7.7A 1.2A 200mA
24VDC/65AH* N/A 7.7A 1.2A
*Note: Additional battery enclosure required
(Figs. 5-7, pgs. 11-13).
Power Supply Board Output Voltage Settings:
+ DC ---
SW1
OFF - 24V
ON - 12V
ON
Fig. 1a - Maximal3V Power Supply Board
Fig. 1b
ON
OFF - 24V
ON - 12V