Datasheet

DS2480B
13 of 32
Table 4. CONFIGURATION PARAMETER VALUE CODES
Value Codes
Parameter Code 000 001 010 011 100 101 110 111 Unit
001 (PDSRC) 15 2.2 1.65 1.37 1.1 0.83 0.7 0.55 V/µs
010 (PPD) 32 64 128 256 512 1024 2048
µs
011 (SPUD) 16.4 65.5 131 262 524 1048 Note
ms
100 (W1LT) 8 9 10 11 12 13 14 15 µs
101 (DSO/W0RT) 3 4 5 6 7 8 9 10 µs
110 (LOAD) 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 mA
111 (RBR) 9.6 19.2 57.6 115.2 9.6 19.2 57.6 115.2 kbps
Note: The value code 110 of parameter 011 (Strong Pullup Duration) must not be used since it could
cause unexpected results.
The syntax of configuration commands is very simple. Each 8-bit code word contains a 3-bit parameter
code to specify the parameter and the 3-bit value code to be selected. Bit 7 of the command code is set to
0 and bit 0 is always a 1. To read the value code of a parameter, one writes all 0s for the parameter code
and puts the parameter code in place of the parameter value code. Table 5 shows the details.
The configuration command response byte is similar to the command byte itself. Bit 0 of the response
byte is always 0. When writing a parameter, the upper 7 bits are the echo of the command code. When
reading a parameter, the current value code is returned in bit positions 1 to 3 with the upper 4 bits being
the same as sent (see Table 6).
Table 5. CONFIGURATION COMMAND CODES
FUNCTION BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
Write Parameter 0 parameter code parameter value code 1
Read Parameter 0 0 0 0 parameter code 1
Table 6. CONFIGURATION COMMAND RESPONSE BYTE
FUNCTION BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0
Write Parameter 0 same as sent same as sent 0
Read Parameter 0 same as sent parameter value code 0