Datasheet
DS2413: 1-Wire Dual Channel Addressable Switch
13 of 18
1-Wire SIGNALING
The DS2413 requires strict protocols to ensure data integrity. The protocol consists of four types of signaling on
one line: Reset Sequence with Reset Pulse and Presence Pulse, Write-Zero, Write-One, and Read-Data. Except
for the Presence pulse, the bus master initiates all falling edges. The DS2413 can communicate at two different
speeds, standard speed, and Overdrive Speed. If not explicitly set into the Overdrive mode, the DS2413
communicates at standard speed. While in Overdrive Mode the fast timing applies to all waveforms.
To get from idle to active, the voltage on the 1-Wire line needs to fall from V
PUP
below the threshold V
TL
. To get
from active to idle, the voltage needs to rise from V
ILMAX
past the threshold V
TH
. The time it takes for the voltage to
make this rise is seen in Figure 11 as '' and its duration depends on the pullup resistor (R
PUP
) used and the
capacitance of the 1-Wire network attached.
The voltage V
ILMAX
is relevant for the DS2413 when determining a
logical level, not triggering any events.
Figure 11 shows the initialization sequence required to begin any communication with the DS2413. A Reset Pulse
followed by a Presence Pulse indicates the DS2413 is ready to receive data, given the correct ROM and PIO
Function command. If the bus master uses slew-rate control on the falling edge, it must pull down the line for t
RSTL
+ t
F
to compensate for the edge. A t
RSTL
duration of 480µs or longer exits the Overdrive Mode, returning the device
to standard speed. If the DS2413 is in Overdrive Mode and t
RSTL
is no longer than 80µs, the device remains in
Overdrive Mode. If the device is in Overdrive Mode and t
RSTL
is between 80µs and 480µs, the device will reset, but
the communication speed is undetermined.
Figure 11. Initialization Procedure: Reset and Presence Pulse
RESISTOR MASTER DS2413
t
RSTL
t
PDL
t
RSTH
t
PDH
MASTER TX “RESET PULSE” MASTER RX “PRESENCE PULSE”
V
PUP
V
IHMASTER
V
TH
V
TL
V
ILMAX
0V
t
F
t
REC
t
MSP
After the bus maste
r has released the line it goes into receive mode. Now the 1-Wire bus is pulled to V
PUP
through
the pullup resistor, or in case of a DS2482-x00 or DS2480B driver, by active circuitry. When the threshold V
TH
is
crossed, the DS2413 waits for t
PDH
and then transmits a Presence Pulse by pulling the line low for t
PDL
. To detect a
presence pulse, the master must test the logical state of the 1-Wire line at t
MSP
.
The t
RSTH
window must be at least the sum of t
PDHMAX
, t
PDLMAX
, and t
RECMIN
. Immediately after t
RSTH
is expired, the
DS2413 is ready for data communication. In a mixed population network, t
RSTH
should be extended to minimum
480µs at standard speed and 48µs at Overdrive speed to accommodate other 1-Wire devices.