Installation Sheet

Page 4 of (4)
Fixture Black
wire
Fixture White
wire
Fixture Green
Ground wire
2
3
1
7
5
6
Remove the kock-out by hammering
Disengage adapter plate by loosening screw. Insert romex connector into the housing open hole
on the adapter plate. Secure it with the nut.
Pull 3 wires out of the fixture to allow connection to
the branch circuit.
Inserting wires into the open hole in the push-in
wire connector
Connect the Green ground input supply wire to the
fixture Green ground wire.
Connect the White input supply wire to the fixture
White wire.
Connect the Black input supply wire to the fixture
Black wire.
**Do not mix wires or change polarity.
4
Feed wires back into fixture, reattach adapter
plate tighten screw, and attach the fixture to the
base of the cabinet, with screws
Fix the fixture to the unit using 2 fixing screws