Photometric Information

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 10
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME:
传统吸顶灯
SPEC.:
MFR.: EVERFINE
TYPE:
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.5V I:1.485A P:178.9W PF:1.000 Lamp Flux:1235.42x1 lm
(DEG)
γ
C(DEG)
Table--2 UNIT: cd
285
0 327
5 326
10 323
15 318
20 311
25 302
30 292
35 279
40 265
45 249
50 231
55 212
60 192
65 172
70 151
75 131
80 112
85 94.6
90 76.1
300
327
326
323
319
312
304
293
281
267
251
234
215
195
175
155
135
115
100
78.7
315
330
329
326
322
315
307
297
285
271
255
237
219
199
179
159
138
119
99.8
81.3
330
330
329
327
323
317
309
299
287
273
257
240
221
202
182
162
141
121
102
83.2
345
330
330
327
323
317
309
299
287
273
258
241
222
203
183
162
142
121
101
82.5
C Range: 0 - 360DEG
C Interval: 15.0DEG
Range: 0 - 90DEG
Interval: 0.5DEG
γ
γ
Test Speed: MEDIUM Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.291
Temperature:25.3DEG Humidity:65.0%
Test Distance:7.500m [K=1.0000]Operators:wxh
Test Date:2016-03-12 Remarks:
C:\Documents and Settings\Administrator\
桌面
\2681MRO1.GOS