Photometric Information
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 10
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME:
传统吸顶灯
SPEC.:
MFR.: EVERFINE
TYPE:
DIM.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:120.4V I:1.982A P:238.7W PF:1.000 Lamp Flux:1646.58x1 lm
(DEG)
γ
C(DEG)
Table--2 UNIT: cd
285
0 425
5 424
10 422
15 418
20 413
25 405
30 394
35 380
40 362
45 341
50 316
55 290
60 262
65 233
70 204
75 176
80 148
85 127
90 104
300
425
424
422
419
413
405
394
379
361
340
315
289
261
232
203
175
148
127
104
315
425
424
422
419
413
404
393
378
360
338
313
286
258
230
201
173
146
125
101
330
424
424
422
419
413
405
393
379
360
339
314
287
259
230
201
173
146
127
100
345
424
423
422
419
413
405
395
380
363
341
317
290
262
233
204
175
148
127
102
C Range: 0 - 360DEG
C Interval: 15.0DEG
Range: 0 - 90DEG
Interval: 0.5DEG
γ
γ
Test Speed: MEDIUM Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.291
Temperature:25.3DEG Humidity:65.0%
Test Distance:7.500m [K=1.0000]Operators:wxh
Test Date:2016-03-15 Remarks:
C:\Documents and Settings\Administrator\
桌面
\11060MROI.GOS