Santa Cruz (MAXREFDES23#) Quick Start Guide Rev 0; 2/14 Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. Maxim Integrated 160 Rio Robles, San Jose, CA 95134 USA 1-408-601-1000 © 2014 Maxim Integrated Products, Inc.
Santa Cruz (MAXREFDES23#) Quick Start Guide Table of Contents 1. Required Equipment ................................................................................................. 3 2. Overview ................................................................................................................... 3 3. Included Files ........................................................................................................... 5 4. Procedure .................................................
Santa Cruz (MAXREFDES23#) Quick Start Guide 1. Required Equipment • • • • • • PC with Windows® 7 (Verify with Balluff that your version of Windows is supported before purchasing their software.) Santa Cruz (MAXREFDES23#) board One Balluff USB IO-Link® master (silver box) with corresponding USB and power cables. This must be purchased separately. Balluff IO-Link Device Tool (tested with version 2.11.1 and comes with the Balluff USB IO-Link master) One IO-Link cable (yellow).
Santa Cruz (MAXREFDES23#) Quick Start Guide Figure 1. Santa Cruz Board Connected to a Balluff USB IO-Link Master Figure 2.
Santa Cruz (MAXREFDES23#) Quick Start Guide 3. Included Files The RD23_RL78_V01_XX.ZIP contains the corresponding IO-Link Device Descriptor (IODD) files. The IODD contains information on communication properties, device parameters, identification, process, and diagnostic data. It includes an XML file, an image of the device, an icon image, and the manufacturer’s logo.
Santa Cruz (MAXREFDES23#) Quick Start Guide 4. Procedure 1. Connect the A-to-B Type USB cable from the PC and yellow IO-Link cable to the Balluff USB IO-Link master (silver box with part number BNI USB-901-000A501) as shown in Figure 1. 2. Connect the Santa Cruz light sensor board to the other side of the yellow IOLink cable. Make sure the green LED is lit as shown in Figure 2. The red and yellow LEDs do not need to be lit. 3. Download the latest “all design files” RD23V01_XX.ZIP file at www.
Santa Cruz (MAXREFDES23#) Quick Start Guide 6. Choose the default installation Folder and press the Next button.
Santa Cruz (MAXREFDES23#) Quick Start Guide 7. Press the Next button.
Santa Cruz (MAXREFDES23#) Quick Start Guide 8. Change the language to English if applicable. 9. Close the program by clicking the X in the top right corner.
Santa Cruz (MAXREFDES23#) Quick Start Guide 10. Press the Close button to complete the installation.
Santa Cruz (MAXREFDES23#) Quick Start Guide 11. Verify the version of the IO-Link Device Tool. In this case, version 2.1.11 was used.
Santa Cruz (MAXREFDES23#) Quick Start Guide 12. Login in Specialist mode using the password special.
Santa Cruz (MAXREFDES23#) Quick Start Guide 13. Import the IODD xml file for the Maxim sensor. In this case, the file is Renesas-RL78-Maxim-Sample-20131007-IODD1.0.1.xml located in the RD23_RL78_V01_00.ZIP file.
Santa Cruz (MAXREFDES23#) Quick Start Guide 14. In this case, this is the IODD file shown below, but may be a different .xml file if a different Maxim sensor is used.
Santa Cruz (MAXREFDES23#) Quick Start Guide 15. See the Maxim Sensor show up in the IO-Link devices in the Catalog window.
Santa Cruz (MAXREFDES23#) Quick Start Guide 16. Select File | Properties.
Santa Cruz (MAXREFDES23#) Quick Start Guide 17. After Properties is selected, the screen looks like the below screenshot. 18. Verify that the USB cable is plugged into the silver USB IO-Link Master box.
Santa Cruz (MAXREFDES23#) Quick Start Guide 19. Drag the Balluff USB IO-Link Master to the Topology window.
Santa Cruz (MAXREFDES23#) Quick Start Guide 20. Drag the Maxim sensor to the Name field in the Common window.
Santa Cruz (MAXREFDES23#) Quick Start Guide 21. Verify a picture of the sensor shows up with the name Renesas-RL78Maxim-Sample.
Santa Cruz (MAXREFDES23#) Quick Start Guide 22. Press the Connect button on the Balluff IO-Link Device Tool Software.
Santa Cruz (MAXREFDES23#) Quick Start Guide 23. If your sensor has a problem or is unconnected, then you will see the below figure.
Santa Cruz (MAXREFDES23#) Quick Start Guide 24. If your sensor is working correctly, then click on the Maxim sensor device icon and then the Oscilloscope tab. Press the Play (triangle button) button. Point the tip of the MAXREFDES23# sensor at the ceiling towards the ceiling lights for a few seconds and then cover the tip of the MAXREFDES23# sensor with your hand, as shown below.
Santa Cruz (MAXREFDES23#) Quick Start Guide Covering up tip of the Santa Cruz light sensor with hand to block light. 25. Press the Stop button to stop the quick 8-bit visual life test.
Santa Cruz (MAXREFDES23#) Quick Start Guide 26. Next, press the Parameter tab and scroll down to the Ambient Light Intensity parameter. Press the Value column to see an on-request parameter read of the Ambient Light Intensity.
Santa Cruz (MAXREFDES23#) Quick Start Guide 5. Appendix A: Project Structure and Key Filenames 6. Trademarks IO-Link is a registered trademark of ifm electronic GmbH. Windows is a registered trademark and registered service mark of Microsoft Corp.
Santa Cruz (MAXREFDES23#) Quick Start Guide 7.