Datasheet
Power-Supply Ranges
Supply Voltage V+ to GND .............................................+6.5V
Differential Input Voltage .........................-0.3V to (V+ + 0.3V)
Common-Mode Input Voltage .................. -0.3V to (V+ + 0.3V)
LATCH Input (MAX941 only) ...................-0.3V to (V+ + 0.3V)
SHDN Control Input (MAX941 only) .........-0.3V to (V+ + 0.3V)
Current Into Input Pins .....................................................±20mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin Plastic DIP (derate 9.09mW/°C above +70°C) ..727mW
8-Pin SO (derate 5.88mW/°C above +70°C) ............... 471mW
8-Pin μMAX (derate 4.1mW/°C above +70°C) ............330mW
14-Pin Plastic DIP (derate 10.00mW/°C above +70°C) ..800mW
14-Pin SO (derate 8.33mW/°C above +70°C) ............. 667mW
Operating Temperature Ranges
MAX94_C_ _ ......................................................0°C to +70°C
MAX94_E_ _ .................................................. -40°C to +85°C
MAX94_AUA ................................................. -40°C to +125°C
MAX942MSA ................................................ -55°C to +125°C
Storage Temperature Range ............................ -65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
(V+ = 2.7V to 5.5V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 14)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Positive Supply Voltage V+ 2.7 5.5 V
Input Voltage Range V
CMR
(Note 1) -0.2 V+ + 0.2 V
Input-Referred Trip
Points
V
TRIP
V
CM
=
0V or
V
CM
= V+
(Note 2)
T
A
= +25°C
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
1 3
mV
MAX941_UA/MAX942_UA 1 4
T
A
= T
MIN
to T
MAX
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
4
mV
MAX941_UA/MAX942_UA 6
Input Offset Voltage V
OS
V
CM
=
0V or
V
CM
= V+
(Note 3)
T
A
= +25°C
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
1 2
mV
MAX941_UA/MAX942_UA 1 3
T
A
= T
MIN
to T
MAX
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
3
mV
MAX941_UA/MAX942_UA 5.5
Input Bias Current I
B
V
IN
= V
OS
, V
CM
= 0V or
V
CM
= V+ (Note 4)
MAX94_C 150 300
nA
MAX94_E/A, MAX942MSA 150 400
Input Offset Current I
OS
V
IN
= V
OS
, V
CM
= 0V or V+ 10 150 nA
Input Differential Clamp
Voltage
V
CLAMP
Force 100μA into IN+, IN- = GND,
measure V
IN+
- V
IN-
, Figure 3
2.2 V
Common-Mode Rejection
Ratio
CMRR (Note 5)
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
80 300
μV/V
MAX941_UA/MAX942_UA 80 800
Power-Supply Rejection
Ratio
PSRR
2.7V ≤ V+ ≤ 5.5V,
V
CM
= 0V
MAX94_C_ _, MAX94_EP_,
MAX94_ES_, MAX942MSA
80 300
μV/V
MAX941_UA/MAX942_UA 80 350
Output High Voltage V
OH
I
SOURCE
= 400μA
V+ - 0.4
V+ -
0.2
V
I
SOURCE
= 4mA
V+ - 0.4
V+ -
0.3
Output Low Voltage V
OL
I
SINK
= 400μA 0.2 0.4
V
I
SINK
= 4mA 0.3 0.4
Output Leakage Current I
LEAK
(Note 6) 1 µA
MAX941/MAX942/
MAX944
High-Speed, Low-Power, 3V/5V, Rail-to-Rail,
Single-Supply Comparators
www.maximintegrated.com
Maxim Integrated
│
2
Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Electrical Characteristics