Datasheet
���������������������������������������������������������������� Maxim Integrated Products 44
MAX9257A/MAX9258A
Fully Programmable Serializer/Deserializer
with UART/I
2
C Control Channel
MAX9257A Register Table (continued)
ADDRESS BITS DEFAULT NAME DESCRIPTION
2
Control channel start timeout: (STO) times out if ECU does not start using control channel within this amount of
time after control channel session is enabled.
7:4 1010 STODIV
Control channel start timeout divider
Pixel clock is first divided by:
0000 = 16 1000 = 256
0001 = 16 1001 = 512
0010 = 16 1010 = 1024 (default)
0011 = 16 1011 = 2048
0100 = 16 1100 = 4096
0101 = 32 1101 = 8192
0110 = 64 1110 = 16,384
0111 = 128 1111 = 32,768
3:0 0000 STOCNT
Control channel start timeout counter
Divided pixel clock is used to count up to (STOCNT + 1)
3
Control channel end timeout: (ETO) times out if ECU does not use control channel for this amount of time after it
has already used at least once.
7:4 1010 ETODIV
Control channel end timeout divider
Pixel clock is first divided by:
0000 = 16 1000 = 256
0001 = 16 1001 = 512
0010 = 16 1010 = 1024 (default)
0011 = 16 1011 = 2048
0100 = 16 1100 = 4096
0101 = 32 1101 = 8192
0110 = 64 1110 = 16,384
0111 = 128 1111 = 32,768
3:0 0000 ETOCNT
Control channel end timeout counter
Divided pixel clock is used to count up to (ETOCNT + 1)