Datasheet

MAX8600/MAX8601
Single-/Dual-Input 1-Cell Li+ Chargers with
OVP Protection and Programmable Charge Timer
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
DC, USB to GND ....................................................-0.3V to +16V
BAT, CT,
CHG, EN, FLT, SETI,
POK, THM, USEL to GND..................................-0.3V to +6.0V
Continuous Power Dissipation (T
A
= +70°C)
14-Pin TDFN 3mm x 3mm Multilayer PCB
(derate 24.4mW/°C above +70°C) ........................ 1951.2mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
ELECTRICAL CHARACTERISTICS
(V
DC
= V
USB
= 5V, V
BAT
= 4V, V
EN
= 0V, R
SETI
= 2kΩ, C
CT
= 0.068µF, T
A
= -40°C to +85°C, unless otherwise noted. Typical values
are at T
A
= +25°C. Note 1)
PARAMETER CONDITIONS
MIN TYP MAX UNITS
DC OR USB (Note 2)
Input Voltage Range 014V
Input Operating Range (Note 3)
4.15 7.00
V
Input Undervoltage Threshold
Input rising, 500mV hysteresis (typ)
3.85
4.0
4.15
V
Input Overvoltage Threshold Input rising, 200mV hysteresis (typ) 7.2 7.5 7.8 V
Input Overvoltage Delay From overvoltage event to charger disabled
0.25
s
Input Supply Current I
BAT
= 0mA, R
THM
= 10kΩ
750 1200
µA
Shutdown Input Current V
EN
= 5V, T
A
= +25°C
275 435
µA
Input to BAT On-Resistance Input = 3.7V, V
BAT
= 3.6V 0.5 0.8 Ω
Input to BAT Dropout Voltage
Input falling, 200mV hysteresis (typ) 5 55
120
mV
BAT
T
A
= +25°C
4.179
4.2
4.221
BAT Regulation Voltage I
BAT
= 0mA
T
A
= -40°C to +85°C
4.166
4.2
4.234
V
BAT Restart Fast-Charge
Threshold
From BAT regulation voltage
-180 -150 -120
mV
R
SETI
= 1.5kΩ
950 1000 1050
R
SETI
= 2kΩ
727 750 773
R
SETI
= 5kΩ
280 300 320
DC Charging Current V
USB
= 0V
Prequal, R
SETI
= 2kΩ, V
BAT
= 2.5V 60 75 90
mA
V
USEL
= 5V
450 475 500
V
USEL
= 0V 80 95
100
USB Charging Current V
DC
= 0V
Prequal, R
SETI
= 2kΩ, V
BAT
= 2.5V 60 75 90
mA
Soft-Start Time Ramp time to fast-charge current 1.2 ms
BAT Prequal Threshold V
BAT
rising, 180mV hysteresis (typ) 2.9 3.0 3.1 V
BAT Leakage Current V
DC
= V
USB
= 0V, V
BAT
= 4.2V
0.001
A
SETI
R
SETI
Resistance Range Guaranteed by charging current 1.5 5.0 kΩ