Table 4. Configuration Register (continued)
REGISTER DATA
REGISTER
ADDRESS
CODE
(HEX)
D7 D6 D5 D4 D3 D2 D1 D0
CONFIGURATION
R/W
INTERRUPT
STATUS
INTERRUPT
OUTPUT
CONTROL
AS GPO
INTERRUPT
ENABLE
GLOBAL
INTENSITY
BLINK FLIP
BLINK
ENABLE
Write device configuration
0
X
Read back device configuration
1
INT
O
O1
O0 I G B E
Disable global intensity control—intensity
is set by registers 0x10–0x17 for ports P0
through P15 when configured as outputs,
and by D3–D0 of register 0x0E for
INT/O16 when INT/O16 pin is configured
as an output port
XXXXX0 XX
Enable global intensity control—intensity
for all ports configured as outputs is set
by D3–D0 of register 0x0E
XXXXX1 XX
Disable data change interrupt—INT/O16
output is controlled by the O0 and O1 bits
XXXX0 XXX
Enable data change interrupt—INT/O16
output is controlled by port input data
change
XXXX1 XXX
INT/O16 output is low (blink is disabled)
XXX00XX0
INT/O16 output is high impedance (blink
is disabled)
XXX10XX0
IN T/O16 outp ut i s l ow d ur i ng b l i nk p hase 0
XXX00XX1
INT/O16 output is high impedance during
blink phase 0
XXX10XX1
IN T/O16 outp ut i s l ow d ur i ng b l i nk p hase 1
XX0 X 0 XX1
INT/O16 output is high impedance during
blink phase 1
XX1 X 0 XX1
Read-back data change interrupt status
—data change is not detected, and
INT/O16 output is high when interrupt
enable (I bit) is set
1
00XXXXXX
Read-back data change interrupt status
—data change is detected, and INT/O16
output is low when interrupt enable (I bit)
is set
1
0x0F
10XXXXXX
X