Datasheet

MAX71020
Single-Chip Electricity Meter AFE
22Maxim Integrated
Table 7. Register Map (continued)
NAME
BYTE
ADDRESS
R/W
DEFAULT
VALUE
DESCRIPTION
LOADED
BY
QUANT_I0 0x026 R/W 0x0000 0000 Truncation/noise compensation for current in phase A Host
QUANT_0 0x027 R/W 0x0000 0000 Truncation/noise compensation for real power in phase A Host
QUANT_VAR0 0x028 R/W 0x0000 0000
Truncation/noise compensation for reactive power in
phase A
Host
QUANT_V0 0x029 R/W 0x0000 0000 Truncation/noise compensation for voltage in phase B Host
QUANT_I0 0x02A R/W 0x0000 0000 Truncation/noise compensation for current in phase B Host
QUANT_0 0x02B R/W 0x0000 0000 Truncation/noise compensation for real power in phase B Host
QUANT_VAR0 0x02C R/W 0x0000 0000
Truncation/noise compensation for reactive power in
phase B
Host
TEMP22 0x03C R/W 0x0000 024D
Temperature reading at 22NC. Used to calculate
temperature deviation from 22NC
Host
GAINADJ_0 0x040 R/W 0x0000 4000
Adjusts the amplitude for voltage inputs VA and VB for
temperature compensation. Default = unity gain.
Host
GAINADJ_1 0x041 R/W 0x0000 4000
Adjusts the amplitude for current input IA. Default =
unity gain.
Host
GAINADJ_2 0x042 R/W 0x0000 4000
Adjusts the amplitude for current input IB. Default =
unity gain.
Host
APULSEW 0x044 R
WPULSE_CTR 0x045 R
Pulse counter for Wh (real power)
WPULSE_FRAC 0x046 R
Pulse generator numerator for Wh (real power)
WSUM_ACCUM 0x047 R
Pulse generator rollover accumulator for Wh (real power)
AVPULSER 0x048 R
VPULSE_CTR 0x049 R
Pulse counter for Wh (real power)
VPULSE_FRAC 0x04A R
Pulse generator numerator for Wh (real power)
VSUM_ACCUM 0x04B R
Pulse generator rollover accumulator for Wh (real power)
0x04C…0x07F
Used by CE for internal variables
CESTATUS 0x080 R
Status of the Compute Engine
BIT
DESCRIPTION
0
Sag status for voltage phase A.
Automatically clears when the voltage
rises above SAG_THR.
1
Sag status for voltage phase B.
Automatically clears when the voltage
rises above SAG_THR.
2
3 Square wave at exact line frequency
31:4
TEMP_X 0x081 R Temperature deviation from TEMP22
FREQ_X 0x082 R Fundamental line frequency in units of (2520.6 x 2
-32
) Hz
MAINEDGE_X 0x083 R
Number of voltage zero crossings of either direction
during the previous accumulation interval